DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 95
Bosch Security Systems | 8/04 | 4998153891C
Table 22: Off-board Zone Pulse Count Time Selections
Pulse Count Time for Off-board Zones
Selection Pulse Count Time Selection Pulse Count Time
0 10 sec 8 20 sec
1 20 second 9 30 sec
2 40 sec 10 40 sec
3 60 sec 11 50 sec
4 80 sec 12 60 sec
5 100 sec 13 90 sec
6 200 sec 14 120 sec
7 300 sec 15 200 sec
Pulse Count/Pulse Count Time Example:
Follow these steps to program a zone function to detect four 60 ms pulses within 10
sec before it declares the zone
off-normal:
1. Enter “4” in the Pulse Count address of the Zone Function you are configuring. “4” identifies the number of
pulses the control panel must receive.
2. Since your time span is 10
sec, this zone function uses a zone scan time of 60 ms and is only for on-board
zones (see left side of Table 21). The selection for 10
sec is 6. Enter “6” into the Pulse Count Time address of
the Zone Function you are configuring.
When using the 24-Hour Door Zone Function Type, Pulse Count Time determines how long the zone
must be faulted when the area is disarmed before creating an alarm on the zone (range of 0.5 to 300
sec).
Options 1, Zone Function ##
Options 1 for Zone Function Types 0 to 2, 5 to 8, 11 to 15
Address: See Table 17 on page 88
Default: See Table 17 on page 88
Selections: 0 to 15
Enter This Data Digit to Select Options
Options 1, Zone Function 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
No Options Enabled
Enable Alarm Event Abort
• • • • • • • •
Voice Verification
Armed for Perimeter Only Mode
• • • • • • • •
Sensor Trouble Monitor
• • • • • • • •
The option chart above applies to all zone function types except the following:
Zone Function Type 3 (24-hr Control Input)
Zone Function Type 4 (24-hr Tamper)
Zone Function Type 10 (Controlled Keyswitch)
The following sub-sections explain how to program the zone function types listed above.
Zone Function Type 9 is reserved and cannot be programmed.