DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 36
Bosch Security Systems | 8/04 | 4998153891C
Local Programming Options
• Address: 0257
• Default: 12
• Selections: 0, 1, 4, 5, 8, 9, 12, 13
Enter This Data Digit to Select Options
Local Programming Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
No Options Selected
•
Enable Installer Mode Reports
•
• • •
Reserved
Keypad Programming Enabled
• • • •
PK32 (Programming Key) Enabled
• • • •
• Enable Installer Mode Reports: If this option is enabled, the control panel sends the following events:
Installer Mode Start {82}, Installer Mode End {83}, and Parameters Changed {98}. If this option is disabled,
these events are only entered in the control panel’s history log.
• Keypad Programming Enabled: If this option is enabled, all control panel parameters can be programmed
from any system text keypad or an Installer Keypad. See “Installer Keypad” and “Installer Mode” in the
DS7200V2 Installer’s Guide (P/N: 4998153893).
• PK32 (Programming Key) Enabled: If this option is enabled, the PK32 Programming Key can send or
receive a program record (the control panel’s parameter settings). See “Programming Key (PK32)” in the
DS7200V2 Installer’s Guide (P/N: 4998153893).
If the “Keypad Programming Enabled” and the “PK32 (Programming Key) Enabled” options are both
disabled, you cannot access the control panel’s programming mode from a keypad. You can still
program the control panel from RPS.