DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 74
Bosch Security Systems | 8/04 | 4998153891C
Guard Code Options
• Address: 0705
• Default: 0 (No Guard Code Options)
• Selections:
− 0 = No Guard Code Options
− 1 = User 28 is a Guard Code
User 28 can be programmed as a Guard Code. The Guard Code only works in the areas to which User 28 is
assigned. The authority level assigned to the Guard Code (User 28) dictates which keypad functions the guard can
use.
For example, Authority Level Configuration Option 1 configures All On arming. If this is set to 0 (zero), the guard
can arm at any time. If the guard’s authority level does not allow All On arming, then the guard can never arm
All On. If the guard’s authority level allows All On arming, the guard can arm the area All On only if the Guard
Code was used to disarm the area.
Authority Level Configuration Options 2 and 3 configure Perimeter Only Arming and Partial On arming. If these
are set to 0 (zero), then the guard can arm in these modes at any time. If the guard’s authority level does not allow
these modes, then the guard can never arm using these modes. If the guard’s authority level allows these modes,
then the guard can arm the area using these modes only if the Guard Code was used to disarm the area.
Authority Level Configuration Option 4 configures system disarming. If this is set to 0 (zero), the guard can never
disarm the system. If the guard’s authority level does not allow disarming, the guard can never disarm the area. If
the guard’s authority level does allow disarming, then the Guard Code can only disarm the system if the system
had a non-silenced alarm.
Authority Level Configuration Options 5-15 operate the same for the Guard Code as they do for any other user
code. Enabling or disabling these options controls which functions the Guard Code can perform.
ABC Keys Text
• Address:
− [A]: 1298 to 1329
− [B]: 1330 to 1361
− [C]: 1362 to 1393
• Default:
− [A]: A Key Text
− [B]: B Key Text
− [C]: C Key Text
• Selections: See Table 3 on page 7
All control panel text is programmed from the text keypad in a special text-programming mode. See Text Entry
Addresses on page 7 for text programming instructions.
Enter up to 16 characters to describe the ABC key sequences.