Keypad Response Options
Address: 0704
Default: 0
Selections: 0 to 3, 6 to 11, 14, 15
Enter This Data Digit to Select Options
Keypad Response Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
No Keypad Response Options
Enable Keypad Tamper Response
• •
• • •
Enable Extinguish Mode
Extinguish Mode Displays Date
Restrict Installer PIN
• • • •
This is a global parameter that affects all keypads.
Enable Keypad Tamper Response: If this option is enabled, the control panel checks for a keypad tamper
response from each keypad. If this option is disabled, the control panel ignores the keypad tamper response.
To use this option, enable it at the control panel by setting Address 0704 to “1,” and enable the
keypad’s tamper jumper pins. See the installation instructions accompanying the keypad for information.
Enable Extinguish Mode: If this option is enabled, the keypads extinguish when there is no activity. The
Power LED is always on, but any other LEDs are blank. The text keypad display also goes blank. Entering a
PIN turns the LEDs on and causes the text keypads to display text. If this option is disabled, the keypads are
never extinguished.
Extinguish Mode Displays Date: If this option is enabled, when the keypad’s display is extinguished, the
text keypad's display shows the date and time on the first line, and the Call for Service Text (see page 26) on
the second line. If this option is disabled, the text keypad's display is blank.
You must select the “Enable Extinguish Mode" option in order to use the "Extinguish Mode Displays
Date” option.
Restrict Installer PIN: If this option is enabled, the Installer’s PIN is restricted. The user must press [#][9][2]
to enable the Installer PIN. Once the Installer PIN is enabled, the installer may enter his PIN and access the
installer functions. If this option is disabled, the Installer’s PIN is always operative, and the Installer PIN can
clear Extinguish Mode.