DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 28
Bosch Security Systems | 8/04 | 4998153891C
System Alarm Reports/Output Options
• Address: 3407
• Default: 7
• Selections: 0 to 7
Enter This Data Digit to Select Options
System Alarm Reports/Output Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
No System Tamper Alarm Reports, No Output
•
Send System Tamper Alarm Reports
•
• • •
Send System Tamper Alarm Restoral Reports
• •
Enable System Tamper Alarm Output
• • •
Reserved
This parameter determines whether tamper alarm and alarm restoral reports are sent, and if the alarm output
operates on a tamper alarm. This parameter only applies to non-zone tampers.
• Send System Tamper Alarm Reports: If enabled, this option sends an alarm report, such as Data Bus
Device Tamper {189} alarm, to the ARC when a non-zone related tamper alarm is generated. Other non-zone
tamper alarms include Data Bus Missing Alarm {187}, Data Bus Trouble Alarm {191}, and Siren Missing
Alarm {193}.
• Send System Tamper Alarm Restoral Reports: If enabled, this option sends an alarm restoral report, such
as Data Bus Device Tamper {190} restoral, to the ARC when a non-zone related tamper condition is restored.
Other non-zone tamper alarm restorals include Data Bus Missing Alarm Restoral {188}, Data Bus Trouble
Alarm Restoral {192}, and Siren Missing Alarm Restoral {194}.
• Enable System Tamper Alarm Output: If enabled, this option activates the alarm output when a non-zone
related tamper alarm, such as Data Bus Device Tamper alarm, is generated. Other non-zone tamper alarms
include Data Bus Missing {187}, Data Bus Trouble Alarm {191}, and Siren Missing Alarm {193}.
4.2.5 Tests
System Test Configuration Options
• Address: 0244
• Default: 5
• Selections: 0 to 15
Enter This Data Digit to Select Options
System Test Configuration Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
System Test Disabled
•
Test Bell
• • • • • • • •
Test Strobe
• • • • • • • •
Test Battery
• • • • • • • •
Send Test Report
• • • • • • • •
This is a global (affects all areas) option.
When the user enters the System Test key sequence ([#][4][1]) at the keypad, the system performs a self-test that
includes the options selected at this parameter. The configuration applies to all areas.
• Test Bell: If enabled, this option makes a “bell test” part of the system test. The control panel activates the
Bell Time (1|5) and Alarm Output (1|8, 1|9, 1|10, 1|11, 1|12, and 8|8) functions for three sec. See Output
Parameters on page 107 for a complete description of output functions.
• Test Strobe: If enabled, this option makes a “strobe test” part of the system test. The control panel activates
the Strobe Output function (1|6) and waits for the user to press [*] to end the test.
Comentários a estes Manuais