Alarm Event Abort Window
Address: 1034
Default: 3 (45
sec)
Selections:
0 to 1 = 15 sec
2 = 30 sec
3 to 15 = 45 sec
This parameter sets the length of time that a user has to enter a valid PIN and cancel an alarm before an alarm
report is sent.
If a user acknowledges a non-fire alarm event by entering their PIN before the Alarm Event Abort Window
expires, the following events occur:
1. The alarm event is aborted. Alarm, Cancel and Restoral reports associated with the alarm are not
transmitted. The alarm event becomes a local only event.
2. The user hears a unique three long beep tone at the keypad.
3. The text keypad indicates the aborted alarm on the display. The LED keypad indicates the aborted alarm
with a slow flash in Alarm Memory.
See Cancel Event Enabled on page 26 and the “Enable Alarm Event Abort” option in Options 1 for Zone Function
Types 0 to 2, 5 to 8, 11 to 15 on page 95 for more information.
This parameter only affects non-fire zones. Fire and Fire with Verification zones are not affected by
enabling this parameter.
Zone Trouble/Restoral from Trouble Report Routing
Address: 1038
Default: 1 (Reports to Destination 1, Events to Log/Printer)
Selections:
0 = No Reports, no Events to Log/Printer
1 = Reports to Destination 1, Events to Log/Printer
2 = Reports to Destination 2, Events to Log/Printer
3 = Reports to Destinations 1 & 2, Events to Log/Printer
4 = Reports to Destination 2 only on Destination 1 Comm Fail Event, Events to Log/Printer
5 = No reports, Events to Log/Printer
Zone Trouble report events include the following:
RF Low Battery {121}
RF Tamper Trouble {121}
Trouble Events {139 to 145}
Restoral from Trouble report events include Restoral from Trouble events {146 – 152}.
See “Communication Failure (Comm Fail)” for a description of the Comm Fail event and “Dialing Attempt
Tables” for dialing sequence in the DS7200V2 Installer’s Guide (P/N: 4998153893).
Enable reporting at the Global Reporting Options parameter (see Global Reporting Options on page
19), and enter at least one phone number (or IP address) for one routing destination (see Phone
Number 1 (2) for Destination 1 (2) on page 9).