Lock Area # Reporting
Address:
Area 1: 0297
Area 2: 0319
Area 3 (DS7240V2 only): 0341
Area 4 (DS7240V2 only): 0363
Default: 0 (Lock Area Disabled)
Selections:
0 = Lock Area Disabled
1 = Lock Area Reports to Routing Destination 1
2 = Lock Area Reports to Routing Destination 2
This parameter locks area reporting to either Routing Destination 1 or Routing Destination 2. If you enable this
parameter for an area, all reports for that area are sent to the selected destination. Routing parameters for the
individual reports are ignored.
For example, if you set this parameter to 1, all reports in the area are sent to Destination 1. If you set this
parameter to 2, all reports in the area are sent to Destination 2.
Area Name Text
Address:
Area 1 Name: 1394 to 1425
Area 2 Name: 1458 to 1489
Area 3 Name (DS7240V2 only): 1522 to 1553
Area 4 Name (DS7240V2 only): 1586 to 1617
Default:
Area 1: Area 1 Name Text
Area 2: Area 2 Name Text
Area 3 (DS7240V2 only): Area 3 Name Text
Area 4 (DS7240V2 only): Area 4 Name Text
Selections: See Key/Character selection chart
All control panel text is programmed from the text
keypad in a special text-programming mode. See Text
Entry Addresses on page 7 for text programming
instructions.
Enter up to 16 characters to describe each area.
Key Character
0 + - 0 * / \ [ ] = > < # §
1 Space . 1 ? ! , @ _ & ~ : ; " ( ) ' ¿ ¡ % £ $ ¥
2 A B C a b c 2 Å Ä Ã å ä á à â ã α β Ç ç
3 D E F d e f 3 É Æ ë é è ê æ Φ δ ε
4 G H I g h I 4 ï í î ì Γ γ η ι
5 J K L j k l 5 Λ κ λ
6 M N O m n o 6 Ö ö Ñ ñ Ø Õ ø ó ò ô õ µ ν ω
7 P Q R S p q r s 7 Π Σ π ρ σ
8 T U V t u v 8 Ü ü ú ù û Θ Υ θ τ υ
9 W X Y Z w x y z 9 ÿ Ξ Ψ ξ χ ψ ζ
* Moves to the address before the text block.
# Moves to the address after the text block.
A Moves cursor to the previous character position in
text block.
C Moves cursor to the next character position in text
block.
The following keys are not used in text programming
and produce an error tone when pressed: [On], [Off],
[Perimeter Only], [No Entry], [Bypass], [System Reset],
and [B].
Press [1] once to clear a character space or to enter a
blank space.