Table 31: Control Panel Events and Reporting Formats (continued)
Event Event as shown in
Control Panel Log
SIA Report Contact ID
Report
Event Description Zone Types
Linked to Event
RPS
Event
Group
Status
Report
54 Cls,Prt,-Dly,Usr
CL Closing
Report
456 Partial Arm
System armed Perimeter Only with
no delay (instant) by User.
10
55 Frc,All,+Dly,Skd
CF Forced
Closing
403 Automatic
O/C
System forced All On with
Entry/Exit Delay by Sked.
10
56 Frc,All,+Dly,KS
CF Forced
Closing
400 O/C
System forced All On with
Entry/Exit Delay by Keyswitch.
10
57 Frc,All,+Dly, RPS
CF Forced
Closing
400 O/C
System forced All On with
Entry/Exit Delay by RPS.
58 Frc,All,+Dly,Tel
CF Forced
Closing
400 O/C
System forced All On with
Entry/Exit Delay by Telephone.
10
59 Frc,All,+Dly,Usr
CF Forced
Closing
401 O/C by
User
System forced All On with
Entry/Exit Delay by User.
10
60 Frc,All,-Dly,RPS
CF Forced
Closing
400 O/C
System forced All On with no delay
(instant) by RPS.
61 Frc,All,-Dly,Usr
CF Forced
Closing
401 O/C by
User
System forced All On with no delay
(instant) by User.
10
62 Frc,Prt,+Dly,Skd
NF Forced
Perimeter Arm
456 Partial Arm
System forced Perimeter Only with
Entry/Exit Delay by Sked.
10
63 Frc,Prt,+Dly,KS
NF Forced
Perimeter Arm
456 Partial Arm
System forced Perimeter Only with
Entry/Exit Delay by Keyswitch.
10
64 Frc,Prt,+Dly, RPS
NF Forced
Perimeter Arm
456 Partial Arm
System forced Perimeter Only with
Entry/Exit Delay by RPS.
65 Frc,Prt,+Dly,Usr
NF Forced
Perimeter Arm
456 Partial Arm
System forced Perimeter Only with
Entry/Exit Delay by User.
10
66 Frc,Prt,-Dly, RPS
NF Forced
Perimeter Arm
456 Partial Arm
System forced Perimeter Only with
no delay (instant) by RPS.
67 Frc,Prt,-Dly,Usr
NF Forced
Perimeter Arm
456 Partial Arm
System forced Perimeter Only with
no delay (instant) by User.
10
68 Reserved
69 Comm Fail
YC
Communications
Fail
354 Failure to
communicate
event
Report failed to reach routing
destination.
12 R S
70 CommFail, AltComm
YC
Communications
Fail
354 Failure to
communicate
event
Report failed to reach routing
destination configured for Alternate
Communication.
12 R S
71 Comm Restoral
YK
Communications
Restoral
354 Failure to
communicate
event
After communication fail, report
sent successfully to routing
destination.
12 R S
72
CommRstl,
AltComm
YK
Communications
Restoral
354 Failure to
communicate
event
After communication fail, report
sent successfully to routing
destination configured for Alternate
Communication.
12 R S
73 Date/Time Change JT Time Changed
625 Time/Date
reset
Date/Time in panel changed. 12 R
74* Duress
HA Hold Up
Alarm
121 Duress
User entered Duress PIN or
pressed Panic key sequence or [Q]
button** on RF Keyfob. The Duress
report is sent in addition to any
other report that the user’s action
would generate.
1
* This event reports a user number + 200 when sent using SIA and Contact reporting formats.
** See [Q] Button Alarm Response Options on page 76 for more information.