Bosch DS7200V2-EXP Guia do Utilizador Página 72

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 156
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 71
DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 72
Bosch Security Systems | 8/04 | 4998153891C
Alarm Output Option for ABC Keys
Address: 0700
Default: 0
Selections: 0 to 7
Enter This Data Digit to Select Options
Alarm Output Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
No Alarm Output for ABC Keys
Alarm Output for [A] Key
• • • •
Alarm Output for [B] Key
Alarm Output for [C] Key
• • • •
Reserved
This parameter assigns an alarm output option to the ABC keys. The alarm output activates for the response type
assigned to each key. This is a global parameter that affects all areas.
ABC Key Reports/Ack Beep Options
Address: 0701
Default: 0
Selections: 0 to 15
Enter This Data Digit to Select Options
ABC Keys Report & Ack Beep Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
No Alarm Report for ABC Keys
Enable ABC Keys Reporting
• • • • • • • •
Acknowledgement Beep for [A] Key
Acknowledgement Beep for [B] Key
• • • • • • • •
Acknowledgement Beep for [C] Key
• • • • • • • •
This is a global parameter that affects all areas.
Enable ABC Keys Reporting: If this option is enabled, the keys report as follows:
[A] Key reports as Zone 100
[B] Key reports as Zone 101
[C] Key reports as Zone 102
Acknowledgement Beep for ABC Keys: If this option is enabled, the keypad beeps when the ARC receiver
acknowledges a report. If the key is not programmed for reports, the beep occurs on activation.