DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 128
Bosch Security Systems | 8/04 | 4998153891C
4.9 Miscellaneous Programming Options
System Trouble Options
Address: 1265
Default: 0
Selections: 0 to 3
Enter This Data Digit to Select Options
System Trouble Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
No Options Selected
Enable AC Fail Trouble Tone
• •
Enable Ground Fault Display and Trouble Tone
Reserved
Reserved
Enable AC Fail Trouble Tone: This option enables the AC Fail Trouble Tone. All keypads sound the
trouble tone when an AC Fail condition occurs. This tone must be silenced from each area.
Enable Ground Fault Display and Trouble Tone: This option enables the Ground Fault display on the
LCD keypad and the accompanying trouble tone (both LCD and LED keypads). All LCD keypads display a
Ground Fault message and all keypads sound a trouble tone when a Ground Fault condition occurs. The
display and tone must be cleared from each area.
If Ground Fault reports are disabled and the Ground Fault Display & Trouble Tone parameter is
disabled, then ground fault events are not logged.
Factory Default
Address: 2944
Default: 0 (Maintain user-specified changes)
Selections:
0 = Maintain user-specified changes
1 = Return all parameters to factory default settings
This parameter restores all of the manufacturer’s default settings for all parameters (including this one)
when a “1” is entered.