DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 128
Bosch Security Systems | 8/04 | 4998153891C
4.9 Miscellaneous Programming Options
System Trouble Options
• Address: 1265
• Default: 0
• Selections: 0 to 3
Enter This Data Digit to Select Options
System Trouble Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
No Options Selected
•
Enable AC Fail Trouble Tone
• •
Enable Ground Fault Display and Trouble Tone
• •
Reserved
Reserved
• Enable AC Fail Trouble Tone: This option enables the AC Fail Trouble Tone. All keypads sound the
trouble tone when an AC Fail condition occurs. This tone must be silenced from each area.
• Enable Ground Fault Display and Trouble Tone: This option enables the Ground Fault display on the
LCD keypad and the accompanying trouble tone (both LCD and LED keypads). All LCD keypads display a
Ground Fault message and all keypads sound a trouble tone when a Ground Fault condition occurs. The
display and tone must be cleared from each area.
If Ground Fault reports are disabled and the Ground Fault Display & Trouble Tone parameter is
disabled, then ground fault events are not logged.
Factory Default
• Address: 2944
• Default: 0 (Maintain user-specified changes)
• Selections:
− 0 = Maintain user-specified changes
− 1 = Return all parameters to factory default settings
This parameter restores all of the manufacturer’s default settings for all parameters (including this one)
when a “1” is entered.