Bosch DS7200V2-EXP Guia do Utilizador Página 35

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 156
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 34
DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 35
Bosch Security Systems | 8/04 | 4998153891C
Remote Programming Options
Address: 0256
Default: 1
Selections: 0, 1, 3, 5, 7
Enter This Data Digit to Select Options
Remote Programming Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Disable Remote Programming
Enable Remote Programming
• • •
Enable Remote Programming Callback
Terminate Remote Programming Session on
Alarm
• •
Reserved
Enable Remote Programming: If this option is enabled, the system answers the phone at the programmed
ring count for remote programming sessions. [#][4][3] can also be used to start a remote programming session
or answer the phone if Address 0213 is set to 0. See RPS Answer Ring Count, Answering Machine Bypass on page
17.
If the programming session is completed successfully, the control panel sends a Valid Remote Access
{103} report.
If you change the control panel parameters during the programming session, it sends a Parameters
Changed {98} report.
If the programming session is terminated with a ‘reset panel’ from RPS, the control panel sends a Reboot
{104} report.
If the programming session is not successfully completed, the control panel sends an Invalid Remote
Access {102} report.
Select the “Enable Remote Programming” option to ensure that the following options operate properly.
Enable Remote Programming Callback: If this option is enabled, the system answers the phone at the
programmed ring count for remote programming sessions. If it determines that the remote programmer is
calling, it disconnects and calls the remote programmer back using the programmed call-back phone
number/IP address (Remote Programming Call Back Number on page 16). When this is enabled, [#][4][3] can also
be used to start a programming session. When a user presses [#][4][3] at the keypad, the control panel calls
RPS. If the callback to RPS is not successful, it sends a Bad Call {101} report.
Terminate Remote Programming Connection on Alarm: If this option is enabled, an alarm on any zone
or any keypad terminates the remote programming session.
Vista de página 34
1 2 ... 30 31 32 33 34 35 36 37 38 39 40 ... 155 156

Comentários a estes Manuais

Sem comentários