AC Fail {1}/Low Battery {22} Report Options
Address: 0224
Default: 7
Selections: 0 to 15
Enter This Data Digit to Select Options
AC Fail, Low Battery Reporting Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
No AC Fail Reports, No Low Battery Reports
AC Fail Reports
• • • • • • • •
AC Restoral Reports
Low & Missing Battery and Restoral Reports
• • • • • • • •
Ground Fault and Restoral Reports
• • • • • • • •
AC Fail, Low Battery and Ground Fault events occur at all keypads for all areas. This parameter enables reporting
of AC power and battery supervision events, and ground fault events.
Enable reporting at the Global Reporting Options parameter (see Global Reporting Options on page
19), and enter at least one phone number (or IP address) for one routing destination (see Phone
Number 1 (2) for Destination 1 (2) on page 9).
The battery is considered low if the nominal voltage on its terminals drops below 12.1 V. The low battery is
considered missing if the nominal voltage on its terminals drops below 10.2 V.
System Status Report Swinger Count
Address: 0225
Default: 0 (Disabled)
Selections:
0 = Disabled
1 to 15
Set this parameter to zero (0) to disable the System Status Report Swinger. System Status reports are sent as they
occur.
Entering a value from 1 to 15 enables System Status Report Swinger and sets the swinger count. Each system
status report has its own swinger counter. When the count is reached that report is no longer transmitted during
the arming cycle.
For example, if you entered 1 at this parameter, the control panel would only transmit one AC fail report, no
matter how many times AC failed and restored during the arming cycle.
Not all System Status Reports follow this Swinger Count. System Status reports that follow the count set in this
parameter are marked with an “S” in Table 31 (see page 138).
To reset the System Status Report Swinger Count, arm and then disarm the control panel.