DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 24
Bosch Security Systems | 8/04 | 4998153891C
Call for Service/System Inactive Options
Address: 0231
Default: 0
Selections: 0 to 15
Enter This Data Digit to Select Options
Call for Service/System Inactive Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
No Options
Call for Service Display at Call for Service
Interval
• • • • • • • •
Call for Service Report at Call for Service
Interval
Call for Service Display at System Inactive
Interval
• • • • • • • •
Enable Weekly Test Reminder
• • • • • • • •
Call for Service Display at Call for Service Interval: If this option is enabled, the keypad displays a “Call
for service” trouble at all keypads in all areas and/or sends a report for Area 1 at the Call for Service Interval.
Press the [System Reset] key to reset the fault in the area to which the keypad is assigned. There is no trouble
tone for the Call for Service Interval event.
Call for Service Report at Call for Service Interval: If this option is enabled, the Call for Service {37}
Report follows System Status routing. The interval is in weeks (00 to 99). See Call for Service Interval on page
23.
Call for Service Display at System Inactive Interval: If this option is enabled, the keypad displays a “Call
for Service” trouble at all keypads and/or sends a System Inactive {136} report for that area at the System
Inactive Interval. See System Inactive Interval on page 23.
Enable Weekly Test Reminder: If this option is enabled, the system keypads display “System Test due,
Press 1 to test.” A reminder is generated eight (8) days after the last user test. There is no trouble tone for this
trouble reminder event. When the user presses [#][4] to view the trouble, the system displays “System Test
due, Press 1 to test.”