DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 104
Bosch Security Systems | 8/04 | 4998153891C
Bypass/Force Arm Report Routing
Address: 1028
Default: 1 (Reports to Destination 1, Events to Log/Printer)
Selections:
0 = No Reports, no Events to Log/Printer
1 = Reports to Destination 1, Events to Log/Printer
2 = Reports to Destination 2, Events to Log/Printer
3 = Reports to Destinations 1 & 2, Events to Log/Printer
4 = Reports to Destination 2 only on Destination 1 Comm Fail Event, Events to Log/Printer
5 = No reports, Events to Log/Printer
This parameter sets the routing for Bypass and Forced reports. See “Communication Failure (Comm Fail)” for a
description of the Comm Fail event and “Dialing Attempt Tables” for dialing sequence in the DS7200V2 Installer’s
Guide (P/N: 4998153893).
Enable reporting at the Global Reporting Options parameter (see Global Reporting Options on page
19), and enter at least one phone number (or IP address) for one routing destination (see Phone
Number 1 (2) for Destination 1 (2) on page 9).
Swinger Count for Alarm Output
Address: 1029
Default: 3
Selections:
0 (Swinger disabled)
1 to 15
Each individual zone has a swinger count for alarm output.
Swinger Shunt reports are not sent for Swinger Shunt for Alarm Output. Zone reports have their own swinger
count (see Swinger Count for Zone Reports on page 105). The Swinger Count is reset on both arming and disarming
of the system, allowing Swinger Shunt to work for both non-24-hour and 24-hour zones. A trouble condition
occurs after Swinger Shunt.
Example: Assume the Swinger Shunt option is enabled, the control panel is armed, no zones are in alarm and the
Swinger Count for Alarm Output is set to 2. Zones 1, 3 and 5 go into alarm. At the end of Bell Time, the Swinger
Count for Alarm Output for Zones 1,3 and 5 decrements from 2 to 1. Since the counter does not reach zero, no
zones are bypassed. A second alarm event for any of those zones bypasses that zone.
When the Swinger Count is set to zero (0), Swinger Count for Alarm Outputs is disabled. The alarm
outputs activate on every new alarm.