DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 20
Bosch Security Systems | 8/04 | 4998153891C
• Burg Alarm After Two Failed Attempts: If this option is enabled, a steady alarm output sounds after two
failed attempts to transmit a burglary alarm report from any zone when its area is armed. Alarm output is
provided even if the zone is not programmed for alarm output. Program Bell Time to at least 3 min. when
using this option. Disable this option if you want to prevent an alarm output from silent zones even when the
system fails to communicate with the receiver. This option only applies to the following output function types:
− 1|8 Alarm: All On, Perimeter Only, and Partial On (Non-Fire 24-hr alarms)
− 1|9 Alarm: Perimeter Only and Partial On Modes (Non-Fire 24-hr alarms)
− 1|10 Alarm: Controlled Zones and 24-hr Zones (Fire and Non-Fire)
See Output Parameters on page 107 for alarm configuration.
The burg alarm output activates after two failed communication attempts even if the zone is set for
silent operation.
Ack Wait Time
• Address: 0222
• Default: 5 (5 sec)
• Selections:
− 0 = 1 second
− 1 to 15 = 1 to 15 sec (1-second increments)
This parameter sets the amount of time the control panel waits for an acknowledgment tone from the ARC
receiver.
Do not change the default value unless advised by Bosch Technical Service.