4.5 Zone Parameters
4.5.1 Location Configuration
The DS7240V2 supports Locations 1 to 40. The DS7220V2 supports Locations 1 to 24. Locations become zones
by configuring the following parameters: Device, Zone Function, Area, and Zone Number. All four of these
parameters must be configured for each location being used in the system. See Table 13 for location parameter
addresses and defaults (defaults are shown in bold).
Table 13: Location Configuration Parameters
Location Parameters
These columns show the addresses and
defaults for each of the four location
parameters. These parameters configure
each location.
Device Parameter Selections
These columns show the selections for the “Device” parameter. The Device parameter tells the control
panel where to find the sensor loop (or transmitter) status for each Location.
Location Device Zone
Function
Area Zone # On-board
Device = 1
DX2010
1
Device = 2
DX2010
1
Doubled
Device = 3
RF Rcvr 1
1,2
Device = 4
RF Rcvr 2
1,2
Device = 5
DACM
3
Device = 6
(optional)
1 0706
(1)
0707
(11)
0708
(1)
0709, 0710
(0,1)
3.65 k Ω when
doubled w/9
DBus Adr 101
Loop 1
DBus Adr 50
Xmitter 1
DBus Adr 51
Xmitter 1
DACM
2 0711
(1)
0712
(11)
0713
(1)
0714, 0715
(0,2)
3.65 k Ω when
doubled w/10
DBus Adr 101
Loop 2
DBus Adr 50
Xmitter 2
DBus Adr 51
Xmitter 2
DACM
3 0716
(1)
0717
(12)
0718
(1)
0719, 0720
(0,3)
3.65 k Ω when
doubled w/ 11
DBus Adr 101
Loop 3
DBus Adr 50
Xmitter 3
DBus Adr 51
Xmitter 3
DACM
4 0721
(1)
0722
(13)
0723
(1)
0724, 0725
(0,4)
3.65 k Ω when
doubled w/ 12
DBus Adr 101
Loop 4
DBus Adr 50
Xmitter 4
DBus Adr 51
Xmitter 4
DACM
5 0726
(1)
0727
(13)
0728
(1)
0729, 0730
(0,5)
3.65 k Ω when
doubled w/ 13
DBus Adr 101
Loop 5
DBus Adr 50
Xmitter 5
DBus Adr 51
Xmitter 5
DACM
6 0731
(1)
0732
(14)
0733
(1)
0734, 0735
(0,6)
3.65 k Ω when
doubled w/ 14
DBus Adr 101
Loop 6
DBus Adr 50
Xmitter 6
DBus Adr 51
Xmitter 6
DACM
7 0736
(1)
0737
(14)
0738
(1)
0739, 0740
(0,7)
3.65 k Ω when
doubled w/ 15
DBus Adr 101
Loop 7
DBus Adr 50
Xmitter 7
DBus Adr 51
Xmitter 7
DACM
8 0741
(1)
0742
(4)
0743
(1)
0744, 0745
(0,8)
3.65 k Ω when
doubled w/ 16
DBus Adr 101
Loop 8
DBus Adr 50
Xmitter 8
DBus Adr 51
Xmitter 8
DACM
9 0746
(0)
0747
(0)
0748
(1)
0749, 0750
(0,9)
Doubled w/ 1
2.2 k Ω
DBus Adr 102
Loop 1
DBus Adr 106
Loop 1; 3.65 kΩ
DBus Adr 50
Xmitter 9
DBus Adr 51
Xmitter 9
DACM
10 0751
(0)
0752
(0)
0753
(1)
0754, 0755
(1,0)
Doubled w/ 2
2.2 k Ω
DBus Adr 102
Loop 2
DBus Adr 106
Loop 2; 3.65 kΩ
DBus Adr 50
Xmitter 10
DBus Adr 51
Xmitter 10
DACM
11 0756
(0)
0757
(0)
0758
(1)
0759, 0760
(1,1)
Doubled w/ 3
2.2 k Ω
DBus Adr 102
Loop 3
DBus Adr 106
Loop 3; 3.65 kΩ
DBus Adr 50
Xmitter 11
DBus Adr 51
Xmitter 11
DACM
12 0761
(0)
0762
(0)
0763
(1)
0764, 0765
(1,2)
Doubled w/ 4
2.2 k Ω
DBus Adr 102
Loop 4
DBus Adr 106
Loop 4; 3.65 kΩ
DBus Adr 50
Xmitter 12
DBus Adr 51
Xmitter 12
DACM
13 0766
(0)
0767
(0)
0768
(1)
0769, 0770
(1,3)
Doubled w/ 5
2.2 k Ω
DBus Adr 102
Loop 5
DBus Adr 106
Loop 5; 3.65 kΩ
DBus Adr 50
Xmitter 13
DBus Adr 51
Xmitter 13
DACM
14 0771
(0)
0772
(0)
0773
(1)
0774, 0775
(1,4)
Doubled w/ 6
2.2 k Ω
DBus Adr 102
Loop 6
DBus Adr 106
Loop 6; 3.65 kΩ
DBus Adr 50
Xmitter 14
DBus Adr 51
Xmitter 14
DACM
15 0776
(0)
0777
(0)
0778
(1)
0779, 0780
(1,5)
Doubled w/ 7
2.2 k Ω
DBus Adr 102
Loop 7
DBus Adr 106
Loop 7; 3.65 kΩ
DBus Adr 50
Xmitter 15
DBus Adr 51
Xmitter 15
DACM
16 0781
(0)
0782
(0)
0783
(1)
0784, 0785
(1,6)
Doubled w/ 8
2.2 k Ω
DBus Adr 102
Loop 8
DBus Adr 106
Loop 8; 3.65 kΩ
DBus Adr 50
Xmitter 16
DBus Adr 51
Xmitter 16
DACM
17 0786
(0)
0787
(0)
0788
(1)
0789, 0790
(1,7)
DBus Adr 103
Loop 1
DBus Adr 106
Loop 1; 2.2 kΩ
DBus Adr 50
Xmitter 17
DBus Adr 51
Xmitter 17
DACM
18 0791
(0)
0792
(0)
0793
(1)
0794, 0795
(1,8)
DBus Adr 103
Loop 2
DBus Adr 106
Loop 2; 2.2 kΩ
DBus Adr 50
Xmitter 18
DBus Adr 51
Xmitter 18
DACM
19 0796
(0)
0797
(0)
0798
(1)
0799, 0800
(1,9)
DBus Adr 103
Loop 3
DBus Adr 106
Loop 3; 2.2 kΩ
DBus Adr 50
Xmitter 19
DBus Adr 51
Xmitter 19
DACM
20 0801
(0)
0802
(0)
0803
(1)
0804, 0805
(2,0)
DBus Adr 103
Loop 4
DBus Adr 106
Loop 4; 2.2 kΩ
DBus Adr 50
Xmitter 20
DBus Adr 51
Xmitter 20
DACM
1
DBus = Data Bus
2
Xmitter = Transmitter
3
DACM = DACM door contact. Integrating the DACM door contact into the security system is optional. See
DACM Configuration on page 135 for instructions on integrating the DACM door contact into the security system.