11-16 Commissioning MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
To explain the individual commissioning steps we refer to the Notes on
Commissioning for the respective subject, if possible.
Detailed information on the parameters is only contained in the
separate documentation "Rexroth IndraDrive, Parameter Description"
(reference list of all IndraDrive parameters).
Configuring the Measuring Systems
Configure controller and encoder (set travel range, if necessary)
See also "Basics on Measuring Systems, Resolution: Notes on
Commissioning" in chapter "Motor, Mechanical Axis System, Measuring
Systems"
Set initial position value; configure distance-coded measuring systems
See "Relative Measuring Systems: Notes on Commissioning" in chapter
"Motor, Mechanical Axis System, Measuring Systems"
Check whether absolute encoder evaluation is possible (depending on
travel range), set initial position value
See "Absolute Measuring Systems: Notes on Commissioning" in chapter
"Motor, Mechanical Axis System, Measuring Systems"
Set position monitors:
axis position monitor (position at time drive is switched on) for absolute
encoders
position difference monitor of motor encoder and external encoder
configure spindle encoder monitor
See "Monitoring the Measuring Systems: Notes on Commissioning" in
chapter "Motor, Mechanical Axis System, Measuring Systems"
Configuring the Mechanical Axis System
Depending on the mechanical properties, make the following settings:
enter load gear ratio
enter feed constant
enter motor encoder gear ratio
enter gear ratio for external encoder
See "Measuring Systems for Motor and Axis Control, Arrangement: Notes
on Commissioning" in chapter "Measuring Systems for Motor and Axis
Control, Arrangement"
Determining the Physical Status Variables
Make scaling settings for position, velocity, acceleration, torque/force and
temperature data.
See "Scaling of Physical Data: Notes on Commissioning" in chapter
"Motor, Mechanical Axis System, Measuring Systems"
Relative Encoders
Absolute Encoders
Position Monitoring