Bosch PIN8 N1 Guia de Resolução de Problemas Página 68

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 728
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 67
4-14 Master Communication MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
C0155 Field bus: max. length for cycl. command val. exceeded
C0156 Field bus: IDN for cycl. actual val. not configurable
C0155 C0157 Field bus: length for cycl. actual values
exceeded
C0158 Field bus: Tcyc (P-0-4076) incorrect
C0159 Field bus: P-0-4077 missing for cycl. command values
Checking the timing parameters for SERCOS communication in
phases 3 and 4 for plausibility and compliance with limiting conditions
C0108 Time slot parameter > Sercos cycle time
C0112 TNcyc (S-0-0001) or TScyc (S-0-0002) error
C0113 Relation TNcyc (S-0-0001) to TScyc (S-0-0002) error
C0114 T4 > TScyc (S-0-0002) - T4min (S-0-0005)
C0115 T2 too small
C0116 T3 (S-0-0008) within MDT (S-0-0089 + S-0-0010)
C0139 T2 (S-0-0089) + length MDT (S-0-0010) > TScyc (S-0-
0002)
Checking the device and motor configuration
C0132 Invalid settings for controller cycle times
C0135 Type of construction of motor P-0-4014 incorrect
C0137 Error during initialization of motor data (->S-0-0021)
C0153 Error at init. of synchr. motor with reluctance torque
Checking the motor and encoder configuration and parameter
contents
C0119 Max. travel range too large
C0120 Error when reading encoder data => motor encoder
C0121 Incorrect parameterization of motor encoder (hardware)
C0122 Incorr. parameteriz. of motor enc. (mechanical system)
C0123 Modulo value for motor encoder cannot be displayed
C0124 Motor encoder unknown
C0125 Error when reading encoder data => optional encoder
C0126 Incorrect parameterization of optional enc. (hardware)
C0127 Incorr. parameteriz. of opt. enc. (mechanical system)
C0128 Modulo value for optional encoder cannot be displayed
C0129 Optional encoder unknown
C0130 Maximum travel range cannot be displayed internally
C0134 Invalid motor data in encoder memory (->S-0-0021)
C0136 Several motor encoders connected
C0140 Rotary scaling not allowed
C0160 Error when reading encoder data => measuring encoder
C0161 Incorr. parameterization of measuring enc. (hardware)
C0162 Measuring encoder unknown
C0163 Modulo value for measuring encoder cannot be
displayed
C0164 Incorrect measuring encoder configuration
Vista de página 67
1 2 ... 63 64 65 66 67 68 69 70 71 72 73 ... 727 728

Comentários a estes Manuais