6-66 Drive Control MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
P-0-0001, Switching frequency of the power output stage
P-0-0038, Torque-generating current, command value
P-0-0049, Effective torque/force command value
P-0-0051, Torque/force constant
P-0-0109, Torque/force peak limit
P-0-0141, Thermal drive load
P-0-0440, Actual output current value (absolute value)
P-0-0441, Overload warning
P-0-0442, Actual value torque limit positive (stationary)
P-0-0443, Actual value torque limit negative (stationary)
P-0-0444, Actual value peak torque limit
P-0-0445, Status word torque/current limit
P-0-0640, Cooling type
P-0-4034, Thermal time constant winding
P-0-4035, Thermal time constant motor
P-0-4037, Thermal short time overload of winding
P-0-4045, Maximum possible continuous current
P-0-4046, Effective peak current
P-0-4058, Amplifier type data
P-0-4059, Electric type data of power section
E2050 Device overtemp. Prewarning
E2051 Motor overtemp. prewarning
E2056 Torque limit = 0
E2061 Device overload prewarning
E8055 Motor overload, current limit active
8057 Device overload, current limit active
F2018 Device overtemperature shutdown
F2019 Motor overtemperature shutdown
F2021 Motor temperature monitor defective
F2022 Device temperature monitor defective
Torque/Force Limitation
The torque/force limit can be freely parameterized by the user and
provides bipolar and unipolar limits.
Parameters for bipolar limits:
S-0-0092, Bipolar torque/force limit value
P-0-0109, Torque/force peak limit
Parameters for unipolar limits:
S-0-0082, Torque/force limit value positive
S-0-0083, Torque/force limit value negative
Pertinent Diagnostic Messages