MPH-02, MPB-02, MPD-02 Handling, Diagnostic and Service Functions 10-13
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
S-0-0025, IDN-list of all procedure commands
The IDNs of all the command parameters available in the drive are stored
in the operating data of the S-0-0025, IDN-list of all procedure
commands parameter.
S-0-0270, Selected IDN list of operation data to backup
The IDNs of those parameters are stored in the S-0-0270, Selected IDN
list of operation data to backup parameter that are to be saved when
the S-0-0293, C2400 Selectively backup working memory procedure
command is executed.
S-0-0279, IDN-list of password-protected operation data
The S-0-0279, IDN-list of password-protected operation data
parameter contains the IDNs of those parameters that can be protected
by a customer password (S-0-0267). By default there havent been any
IDNs entered in this parameter.
S-0-0327, IDN list of checksum parameter
The parameter S-0-0327, IDN-List of checksum parameter contains the
IDNs of those parameters from which the content of parameter S-0-0326,
Parameter checksum is to be generated. By default there havent been
any IDNs entered in this parameter.
P-0-0013, List of all IDNs not corresponding to default
value
All parameters the operating data of which was changed with regard to
the default value are stored in parameter P-0-0013, List of all IDNs not
corresponding to default value.
Using a Password
Brief Description
IndraDrive controllers provide the possibility to protect parameter values
against accidental or unauthorized change by means of a password. With
regard to write protection, there are 3 groups of parameters that can be
written:
Parameters that are write-protected as a standard, such as motor
parameters, hardware code parameters, encoder parameters, error
memory etc. ("administration parameters"). The values of these
parameters guarantee correct function and performance of the drive.
Parameters the customer can combine in groups and protect them
with a so-called customer password. This allows protecting parameter
values, that are used for adjusting the drive to the axis, after having
determined them.
All other parameters that can be written and are not contained in the
above-mentioned groups. They are not write-protected.