MPH-02, MPB-02, MPD-02 Extended Drive Functions 9-43
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Pertinent Parameters
S-0-0398, IDN list of configurable data in signal status word
S-0-0399, IDN list of configurable data in the signal control word
P-0-0300, Digital I/Os, assignment list
P-0-0301, Digital I/Os, bit numbers
P-0-0302, Digital I/Os, direction
P-0-0303, Digital I/Os, status display
Pertinent Diagnostic Messages
C0246 Trav. range lim. switch not ass. to dig. input
C0247 Dig. output already assigned to another axis
C0248 Dig. input assigned differently to axes
C0249 Dig. I/Os: bit number too large
F2010 Error when init. digital inputs/outputs
F2033 External power supply X10 error
Digital Inputs/Outputs on Optional Module MD1
It is possible to individually configure a digital I/O extension for the
configurable advanced control sections.
The optional module MD1 can be used for the following purposes:
making available digital I/Os for external control unit
enabling input/output of drive parameters
making available digital I/Os for drive-integrated PLC
(IndraMotion MLD-S)
extension of memory (32 kB non-volatile memory) for drive-integrated
PLC
Note: Utilization of digital I/O extension by using the optional module
MD1 is only possible for advanced control sections!
connection via 25-pin D-Sub connector
all inputs/outputs (except for the relay contact) designed for level of
0 V (LOW) or 24 V (HIGH)
separate 24 V supply of the digital outputs
inputs/outputs galvanically isolated
assignment of inputs/outputs to internal parameters or bits
parameters P-0-0081 and P-0-0082 can be completely assigned to
parameters of the drive or of the integrated PLC
free configuration of the digital inputs/outputs via S-0-0144, Signal
status word and S-0-0145, Signal control word
12 digital inputs (freely configurable and protected from reverse
polarity)
8 digital outputs (max. output current 0.5 A and sustained short-circuit-
proof)
Features