MPH-02, MPB-02, MPD-02 Motor, Mechanical Axis System, Measuring Systems 5-43
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
()
St)-(AISt)-R(Al
St)-H(AlSt)-
RR
40410P40400P
R
L L
4043-0-P
+
=
+
=
R
R(Al-St)
: ohmic resistance of rotor at 20°C
L : leakage inductance of rotor
L
H(Al-St)
: motor magnetizing inductance
Fig. 5-57: Value for P-0-4043 (in ms)
Determining Other Parameter Values only Relevant for
Synchronous Motors
0111)-0-S (2,04005-0-P
or
0109)-0-(S 4005-0-P
=
=
S-0-0109, Motor peak current
S-0-0111, Motor current at standstill
Fig. 5-58: Values for P-0-4005; the value with the lower absolute value has to
be entered with negative sign in P-0-4005!
Depending on the position of the primary part of the motor with regard to
the secondary part of the motor, different inductance values can be
observed when the leakage inductance is measured. The values are
fluctuating between a minimum and a maximum value.
The minimum value is relevant for the direct-axis inductance of the
motor (L
L(U-V)
).
The maximum value is relevant for the quadrature-axis inductance of
the motor (L
Q(U-V)
).
Note: Correct values can only be determined when the motor is in
standstill!
The value for the direct-axis inductance of motor contained in the
completed form "Output Data for Synchronous Motors" has to be used for
calculation as follows:
0,5 L4016-0-P
V)-L(U
=
L
L(U-V)
: value according to motor output data
Fig. 5-59: Value for P-0-4016
The value for the quadrature-axis inductance of motor contained in the
completed form "Output Data for Synchronous Motors" has to be used for
calculation as follows:
0,5 L 4017-0-P
V)-Q(U
=
L
Q(U-V)
: value according to motor output data
Fig. 5-60: Value for P-0-4017
list parameter P-0-4002
enter the value "1,0" in each of the five lines!
list parameter P-0-4003
enter the value "1,0" in each of the five lines!
P-0-4005, Flux-generating
current, limit value
Direct-Axis Inductance of Motor
and Quadrature-Axis Inductance
of Motor
P-0-4016, Direct-axis inductance
of motor
P-0-4017, Quadrature-axis
inductance of motor
P-0-4002, Charact. of
quadrature-axis induct. of motor,
inductances
P-0-4003, Charact. of
quadrature-axis inductance of
motor, currents