5-30 Motor, Mechanical Axis System, Measuring Systems MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Note: For more details on motor measuring system, motor holding
brake, motor temperature evaluation and default control loop
parameters see respective subchapter of this documentation!
Pertinent Diagnostic Messages
Diagnostic messages with regard to command "C3200 Calculate data for
asynchronous motor":
C3201 Incorrect input for current
C3203 Incorrect input for voltage
C3202 Incorrect input for frequency
C3204 Incorrect input for speed
C3205 Incorrect input for power factor
C3206 Incorrect input for power
C3207 Type plate list incomplete
C3208 Error when writing parameters
Hardware Data
For the electrical connection of the motors to the controller see the
Project Planning Manuals for the IndraDrive controllers. A complete
connection diagram for the use of Rexroth motors is contained in the
respective Project Planning Manual.
Third-Party Motors to be Controlled
The following motor types can be controlled:
asynchronous motors, rotary
asynchronous motors, linear
synchronous motors, rotary
synchronous motors, linear
These motors can be operated within the scope of the technical data of
the IndraDrive controller selected for motor control, if these motors have
been equipped with holding brakes.
Note: For third-party motors Bosch Rexroth, as a matter of principle,
does not assume the guarantee for the power data at the
motor shaft!
In the case of synchronous motors, the commutation offset has to be set
first during commissioning. For synchronous third-party motors at
IndraDrive devices this offset is determined with the "saturation method".
Note: For application-specific limitations for synchronous motors in
conjunction with the saturation method see "Motor Control:
Commutation Setting" in chapter "Drive Control"!
The control section integrated in the controller can evaluate the
measuring systems as a motor encoder that are contained in P-0-0074,
Encoder type 1 (motor encoder) (see also product documentation of the
IndraDrive control sections).
Motor Types
Motor Encoder
Vista de página 153