10-8 Handling, Diagnostic and Service Functions MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
To load saved parameter values or transmit axis-specific parameter
values to controllers of other axes there are the following possibilities:
• Start P-0-4091, C2500 Copy IDN from optional memory to internal
memory
The parameter values (according to list of S-0-0192) stored on a
plugged MMC are loaded to the device-internal, non-volatile flash
memory.
• "DriveTop" commissioning tool
The parameter values (according to list of S-0-0192) stored on an
external data carrier (hard disk, floppy disk or the like) are loaded to
the controller; source assignment is carried out via the menu of the
tool (serial communication with the controller or via SERCANS-
Box/SERCOS interface).
• Control master
The parameter values of the list of S-0-0192 or S-0-0270 and/or other
parameters, if necessary, are loaded to the controller from a master-
side data carrier by command of the control master.
When reading the S-0-0326, Parameter checksum parameter the
checksum of all parameter values is generated the IDNs of which are
contained in parameter S-0-0327, IDN list of checksum parameter.
Changes in the parameter settings can be detected by comparing the
checksums.
By comparing the checksum of the parameter values currently active in
the drive to a checksum value stored at the time of parameter saving, it is
possible to determine whether the active application-specific parameter
values are correct.
By default there haven’t any IDNs been entered in parameter S-0-0327!
Notes on Commissioning
At the beginning of the initial commissioning of a motor or a machine axis,
first make sure the desired firmware is active in the drive. To do this, read
parameter
• S-0-0030, Manufacturer version.
If the desired firmware is not available in the controller, carry out a
firmware update (see "Firmware Update" in chapter "Handling, Diagnostic
and Service Functions").
If the desired firmware is available in the controller, load basic parameter
values of the firmware:
1. set P-0-4090, Index for C07 Load defaults procedure
2. start S-0-0262, C07_x Load defaults procedure command
Respective diagnostic command message:
• C07_1 Load defaults procedure com. (load basic parameters)
Respective diagnostic messages in the case of possible command errors:
•
C0751 Parameter default value incorrect (-> S-0-0021)
• C0752 Locked with password
• C0753 ’Load basic parameters’ not allowed in phases 3 and 4
See also "Initial Commissioning/Serial Commissioning" in chapter
"Commissioning"
Loading Application-Specific
Parameter Values
Parameter Checksum
Initial Commissioning
Load Basic Parameters