Rexroth SYNAX 200 Motion control configuration 4-35
DOK-SYNAX*-SY*-12VRS**-PR01-EN-P
Ambient conditions BTV 16, BTV 40
During operation During storage/transport
Max. ambient temperature + 5 ... + 45°C-20°C to +60°C
Max. temperature gradient time temperature changes up to
3°C per minute
not defined
Relative humidity climate class 3K3 according to EN
60721, condensation not permitted
climate class 3K3 according to
EN 60721, condensation not
permitted
Atmospheric pressure up to 2000 m altitude according to
DIN 60204
Mechanical strength Max. vibration :
frequency range: 10...150 Hz
deflection: 0,075 mm
at 10...57 Hz
acceleration: 1 g
at 57...150 Hz
according to EN 60068-2-6
Max. shock:
15 g according to DIN IEC 68-
2-27, no failure of the function
Fig. 4-60: Ambient conditions BTV 16/BTV 40
Wear parts BTV 16, BTV 40
• The service life of the backlight is limited to a certain number of
operating hours. After this time the backlight will produce only 50 % of
its original brightness. This time differs for the used displays:
• 12": 40.000 hours
• 15": 35.000 hours
• CMOS battery: 5 to 7 years
• accumulator pack: the number of the practicable load cycles of the
accumulator pack and thus the service life depends on the ambient
temperature the accumulator is used. In this case the ambient
temperature defines the temperature where the operator input terminal
or the accumulator pack is placed, e.g., the inside temperature of the
control cabinet or a control panel housing.
Ambient temperature Load cycles Service interval
25°C 4000 cycles 6 years
35°C 2000 cycles 3 years
45°C 1000 cycles 1,5 years
Fig. 4-61: accumulator pack
The operation out of this typical conditions is permissible, whereby,
however, the service life of the hard disk may be reduced. However,
the ambient conditions specified for the overall device have to be
absolutely kept.
• Also fans are mechanic wear components, whose service life is
extremely temperature-dependent. For the fan integrated in the
housing the manufacturer specifies the following service life:
Ambient temperatur Service life
40 ° C 70 000 hours
70 ° C 35 000 hours
Fig. 4-62: Service life of the fan
Wear parts that are without
guarantee