Rexroth SYNAX 200 Drive configurations 5-37
DOK-SYNAX*-SY*-12VRS**-PR01-EN-P
5.4 Determining the control-related I/O option
Determining parallel I/Os (IndraDrive with option MD1)
In the IndraDrive a parallel I/O option card HEA01 can be used (option
MD1).
Binary signals can be exchanged with this card between the PPC and a
PLC. The voltage level equals 24 volts. The inputs and outputs are opto-
decoupled.
12 inputs and 8 outputs are available.
The signals applied to this I/O are transmitted via the SERCOS fibre-
optics cable link to the PPC.
Determining parallel I/Os (Diax)
DEA04 or DEA08 parallel I/O cards can be inserted into DKR and HDS
controllers.
Binary signals can be exchanged with this card between the PPC and a
PLC. The voltage level equals 24 volts. The inputs and outputs are opto-
decoupled.
Fifteen inputs (the 16th input monitors the 24 V power source) and 16
outputs are available. The 16th input can be used as a watchdog or a
regular output.
32 inputs, 24 outputs and a watchdog output are available.
The signals applied to this I/O are transmitted via the SERCOS fibre-
optics cable link to the PPC.
YF000194V01_EN.FH7
15 inputs
16 outputs
DEA04
parallel I/O
in the slot of
a DKR/HDS
24V
Fig. 5-55: Parallel I/O card DEA04
YF000195V01_EN.FH7
32 inputs
24 outputs
DEA 08
parallel I/O
in the slot of
a DKR/HDS
24V
Fig. 5-56: Parallel I/O card DEA08
HEA01
DEA04
DEA08
Comentários a estes Manuais