4-22 Motion control configuration Rexroth SYNAX 200
DOK-SYNAX*-SY*-12VRS**-PR01-EN-P
4.14 Installation instructions PPC-P control
The PC board of the PPC-P is mounted on the right of the front faceplate,
when viewed from inside the PC (standard PCI mounting). Optional
interface cards (e.g., fieldbus cards) have a small board mounted to the
left of the front faceplate.
PPC-P
Optional Interface board
(ISA mounting)
PPC-P PC board
(PCI mounting)
View from
inside PC
YF000163V01_EN.FH7
Fig. 4-33: PC board PPC-P and front faceplate (slot plate)
It is recommended that the plug-in cards that are placed beside the PPC-
P (e.g., with optional interface cards) do not collide with this PC board
allocations.
CAUTION
Improper installation of PCI and ISA cards in the
PC can cause unwanted contact between
boards.
⇒ Install cards to allow sufficient space between
adjacent boards (maybe free a slot between).
PPC-P
PPC-P
PCI Card
Optional PPC-P Interfaces, such as Link
Ring or Option Card PLS, are installed to
the left (when viewed from inside PC) to
allow connection of the PC104 card.
Proximity of cards can
cause unwanted contact
Recommended Installation Improper Installation
PCI Card
YF000164V01_EN.FH7
Fig. 4-34: Installation of the PPC-P with several PCI cards in the PC