6-18 Order data/reference lists Rexroth SYNAX 200
DOK-SYNAX*-SY*-12VRS**-PR01-EN-P
Output module RMA02.2-16-DC024-200
SG100025V01_NN.bmp
Fig. 6-35: RMA02.2-16-DC024-200
The digital 24VDC output modules are designed for the connection of
digital actuators, such as solenoid valves, contactors, or indicator lights.
The 16 outputs are FET transitor switches (active 1 switching) that are
arranged in 2 isolated groups of 8 outputs each. Each 24V output can
source loads up to 2 A.
A detailed description can be found in documentation "SERCOS I/O Unit
RECO02.2 - Project Planning Manual" (DOK-CONTRL-RECO02.2***-
PRJ1-EN-P).
Specifications:
- FET - output switch for 24V DC
- output current I
L
= 2A per output
- internal current limitation
- short-circuit-proof
- 2 isolated blocks
with 8 outputs each
- with internal voltage monitoring of
the externally applied voltage
- power loss P
v
ca. 7,5W
- weight ca. 280g
1
2
3
4
5
6
7
8
11
12
R
MA02.2-16-DC024-200
+U
L
0V
L
9
10
+U
L
0V
L
+
+
-
= 24 VDC
external
power
supply
Q*.0.0
Q*.0.1
Q*.0.2
Q*.0.3
Q*.0.4
Q*.0.5
Q*.0.6
Q*.0.7
Q*.1.0
Q*.1.1
Q*.1.2
Q*.1.3
Q*.1.4
Q*.1.5
Q*.1.6
Q*.1.7
SF100004V01_EN.FH7
X1 X2
Fig. 6-36: General specifications and pin assignments RMA02.2-16-DC024-200
Brief description
RMA02.2-16-DC024-200
Documentation
RMA02.2-16-DC024-200
General specifications
RMA02.2-16-DC024-200