Rexroth SYNAX 200 Motion control configuration 4-7
DOK-SYNAX*-SY*-12VRS**-PR01-EN-P
Ethernet/IP slave or Ethernet (option T2, option card
ETH01)
The option card EHT01 offers a Ethernet/IP slave or a Ethernet interface.
It can only be used with PPC-P11, with PPC-R21 and PPC-R22 the
functionality is on-board.
A transmission rate of 10 MBit/s is supported.
The functionality contains
• Ethernet/IP slave with cyclic transmission of binary I/O data, word and
double word parameters or cyclic transmission of binary I/O data,
word and double word parameters (within UDP/IP) of 4 different
Ethernet master (PLC),
• Ethernet/IP slave with non-cyclic transmission of all parameters and
I/O data of 1 Ethernet/IP master or proprietary RIN protocol within
TCP/IP with 4 different Ethernet master (PLC),
• non-cyclic transmission of all parameters (proprietary RIN protocol
within TCP/IP) of 7 different Ethernet master (SynTop, HMI),
• the support of a bus length of 32 words. With the help of the so called
multiplex channel, parts of the cyclic transmission can be multiplexed,
to transmit further data.
With PPC-R21 and the PPC-R22 the Ethernet interface is on-board.
The same features are supported as with interface option T2 (ETH01),
10/100 MBit/s is supported as transmission rate.
PPC link (option Q1, option card DAQ03)
Several PPC motion controls can be combined to create one PPC link.
The PPC link makes it possible to assign following axes to different
master axis.
Up to 32 PPC motion controls can be combined to one PPC link.
The combination of PPC motion controls is accomplished with the help of
the plug-in card DAQ. All DAQ assemblies are connected with a fibre-
optics cable ring thereby creating the PPC link.
The communication within the PPC link implements, as does the SYNAX
200 ring, a fibre-optics cable ring.
The PPC link can be built on a single or a double fibre-optics-cable ring.
ETH01 only with PPC-P11
Ethernet on-board with PPC-R21
and PPC-R22