D7212GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 73
Bosch Security Systems, Inc. | 1/08 | F01U003804-04
A# Area Fault
Default: Blank
Selection: Blank, 1 to 24, A, B, or C
Activates whenever a controlled (
P## Type 1, 2, 3
only) Perimeter or Interior point is faulted. The relay
remains active until all Perimeter and Interior points in
the area are normal.
Keyswitch area armed status with LEDs:
Use a D8129 Module and connect an LED
to indicate that the area is not ready to arm.
A# Duress Relay
Default: Blank
Selection: Blank, 1 to 24, A, B, or C
Activates when a Duress alarm is generated from a
keypad assigned to the specified area.
Burg Time needs a bell period programmed
and A# Duress Enable must be Yes. This
relay activates when the Burg Bell starts
and deactivates when the Burg Bell time
ends. The Burg Bell pattern has no effect
on this relay function.
A# Perim Fault
Default: Blank
Selection: Blank, 1 to 24, A, B, or C
Activates when a Controlled Perimeter point (
P##
Type 1
) assigned to the specified area is faulted,
regardless of the armed state of the area. This relay
provides a steady output until all Perimeter points in
the area return to normal.
This relay does not activate on interior
faults. To detect all area point faults,
program all points as Perimeter points in
the area where this relay is assigned.
A# Silent Alarm
Default: Blank
Selection: Blank, 1 to 24, A, B, or C
This relay activates when a point assigned to the
specified area and programmed for
P## Silent Bell
goes into alarm.
Alternate Functions for A# Silent Alarm
• Area 4: For time control, programming any value
other than 60 in the Silent Alarm Relay for Area 4
enables AC (traditional) time control. Entering a
value of 60 for Area 4 disables AC time control
and switches the time control to the on-board
crystal. This alternate function is replaced by the
CrystalTime Adj
prompt (refer to page 131) in
the GV2AUX handler for the D7212GV2 in
firmware v7.07 and later.
• Area 5: Programming a non-zero value in the
Silent Alarm Relay for Area 5 enables
Ground
Fault Detect
on the D7212GV2 Control Panel
using firmware version 7.01 and 7.02 only. In
version 7.03 and above, this setting is not used.
Refer to Ground Fault Detect in the D7212GV2
Operation and Installation Guide (P/N:
F01U003805).
• Area 7: Perimeter Armed Relay, when enabled,
turns the Fail to Close Relay function into a
Perimeter Armed Relay function.
To change the Fail to Close Relay into a Perimeter
Armed Relay function, program 63 in the Silent
Alarm Relay for Area 7. Set
A# Fail to Close
Relay
to the area to be Perimeter Armed. Refer to
Area 8 for additional information. This alternate
function is replaced by the
Perimeter Relay
prompt (refer to page 131) in the GV2AUX
handler for the D7212GV2 in firmware v7.07 and
later.
• Area 8: Programming a value of 64 in the Silent
Alarm Relay for Area 8 causes the Area Armed or
Perimeter Armed Relay (refer to Area 7) to activate
at the beginning of the exit delay time. This
alternate function is replaced by the
EarlyArmed
Relay
prompt (refer to page 131) in the GV2AUX
handler for the D7212GV2 in firmware v7.07 and
later.