D7212GV2 | Program Entry Guide | 5.0 RADXSKED EN | 111
Bosch Security Systems, Inc. | 1/08 | F01U003804-04
Default: Blank
Selection: 1 to 11, 13 to 24, 28, 29
S## Cmd Center
Default: Blank (0)
Selections: Blank (0), 1 to 8
Blank (0)
No keypad is
specified for
Custom Function
activation.
Identify the specific keypad
(CC #) where the Custom
Function is entered. Only one
keypad can be assigned for this
sked function.
1 to 8
Command center
(keypad) address
specified for
Custom Function
activation.
S## Custom Func
Default: Blank (0)
Blank (0)
No Custom
Function is
activated.
11 Execute Custom Func: This
function emulates any of the custom
functions assigned to the keypad that
can be executed by a user from the
keypad. When a sked executes a
custom function, it is subject to the
scope of the selected keypad.
Cmd
Center
and
Custom Func
prompts
appear after entering Function Code
11. Both entries are required.
Selections: Blank (0),
128 to 131 for D7212GV2
Enter the custom function this
sked executes.
128 to
131
Custom Function
to activate.
Avoid having multiple functions occur at the same time at the same address. Functions can clash and
the effect on the control panel is unpredictable.
Ensure that the Custom Function being executed or any of the commands nested inside the Custom
Function are not pass-code protected.
Do not program multiple skeds to execute at the same keypad during the same time.
Do not program skeds to execute at times when a user is likely to be executing functions at the keypad.
If it is necessary to do so, there are two ways to work around the situation:
1. Program CC at the beginning of the Custom Function Key Strokes entry. This aborts the user’s
function and allows the sked to execute.
2. Program the sked to execute at an address (Cmd Center) with no keypad physically attached to it.
The CC # must be assigned to an area and have the appropriate scope programmed.
Default: Blank
Selection: 1 to 11, 13 to 24, 28, 29
13 Adjust Time Forward One Hour: This sked function is used to make adjustments to the control panel’s
clock. A typical application is to program this to go into effect at 2:00 AM on the date that Daylight
Saving Time begins (during the springtime). No Time Change Report is sent or logged, but the new time
appears in the next report logged.
No other parameters require input for this option.