D7212GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 67
Bosch Security Systems, Inc. | 1/08 | F01U003804-04
L## Service Walk
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
33 Service Walk Test (Menu function only)
Start a Service Walk Test for all 24-hour Interior or
Perimeter Controlled points in the control panel.
Points are not included in this test if:
Points are in an area that is already in a Walk Test
Mode.
Points are assigned to an area that is not enabled
A# Area On
.
Points are in an area that is Master or Perimeter
armed.
When a Service Walk Test is initiated, one person can
test all the points in the control panel without
assistance. The following features are provided with
the Service Walk Test:
Display indicates exactly how many points can be
tested.
Battery and bell tests do not occur during this
Walk Test.
The test ends when all points are tested or the test
times out after 20 min of inactivity.
Events print locally without alarm annunciation or
reporting to the central station receiver.
D1255 Keypad displays a sequential count and the
text for the point after each point is activated and
restored.
The D1255 Keypad displays ALL PNTS TESTED.
If enabled in Routing, Service Start and Service
End are reported at the central station receiver for
the beginning and end of the test.
Point 128 appears as missing. This is normal. This
points is used for supervising the Zonex 1 bus (Point
128). If the Zonex bus has a fault, these points indicate
a short.
This function allows viewing of extra points. Extra
points occur under two conditions: an extra point is
wired electrically to the Zonex bus with a blank
P###
Point Index
, or two Zonex devices exist for the same
Zonex address.
L## Default Text
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
34 Default Text [COMMAND][5][7]
Temporarily show the armed state of the area using
control panel default text, A# AREA # IS ON, A#
NOT READY, A# AREA # IS OFF, and A#
ACCOUNT IS ON.
L## Change Skeds
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
35 Change Skeds [COMMAND][5][2]
Change skeds that can be edited.
Editing of skeds can be restricted by
programming S## Time Edit? to No.
L## Invisible Walk Test
Default: Refer to the program record sheet
Selection:
Blank, or E
Function No. Function Name Alternate Keystroke
36 Invisible Walk Test (Menu function only)
Test all points that are programmed to be invisible and
that are within the scope of the keypad without
sending reports to the central station. Invisible points
must be programmed P## Invisible Pt as Yes. This
walk test mode can test 24-hour points and controlled
points.
Invisible Test? allows the user with this L## to start
an invisible walk test for all 24-hour interior and
posterior controlled points in the area to which this
keypad is assigned. When an invisible test is started,
one person can test invisible points without assistance.
The following features are provided with the Invisible
Test Mode:
The display indicates exactly how many invisible
points are assigned to the area.
Battery and bell tests do not occur during this walk
test.
The keypad shows point text when invisible points
are tested.