D7212GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 54
Bosch Security Systems, Inc. | 1/08 | F01U003804-04
Figure 3: Softkey Locations on the D1260 Keypad
1
2
ABC
3
DEF
4
GHI
5
JKL
6
MNO
7
PRS
8
TUV
9
WXY
0
COMMAND
*
ENTER
#
7
1
2
3
4
6
8
5
1 - Softkey 1 (C1)
2 - Softkey 2 (C2)
3 - Softkey 3 (C3)
4 - Softkey 4 (C4)
5 - Softkey 5 (C5)
6 - Softkey 6 (C6)
7 - Softkey 7 (C7)
8 - Softkey 8 (C8)
Programming Custom Function Keystrokes
Find the command you want to execute in the User
Interface section of the program record sheet.
Single digit commands must be programmed with
9 as the second digit.
Table 23: CF### Custom Function Keystrokes
Command Keystroke
1 (Master arm area) A19
2 (Perimeter instant arm) A29
3 (Perimeter delay arm) A39
6 (Watch Mode) A69
7 (Special alert) A79
8 (Perimeter partial arm) A89
9 ( Special alert) A99
0 (Bypass a point) A09
When
CF### Custom Function
is programmed
with P, the corresponding custom function number
is passcode protected. The
CF### Custom
Function
prompt is under GV2MAINUser
InterfaceCnd Center Functions. The passcode
protected custom function can be added to a
keypad’s function list by programming its number
in the GV2MAIN > Function List > M# Function
prompt.
128 to 131 Enable Custom Function 128
through 131, (Menu Function only): This
function determines if a passcode is needed to
access a Custom Function from the menu list.
ENTER PASSCODE (or Enter Passcode +
Enter Key on the D1260) appears when this
function is pass-code protected.
If a command within the Custom Function
is pass-code protected, ENTER
PASSCODE appears at the keypad. The
user must enter a valid passcode must be
entered before proceeding with the rest of
the Custom Function. If a passcode is not
entered within 10 sec, the Custom
Function times out and the display returns
to idle text.
Skeds cannot execute Custom Functions
that are pass-code protected. The D720
LED keypad does not support Custom
Functions that are pass-code protected.
Some functions cannot be entered directly because
they are nested inside a higher-level function. To
automatically execute these functions, you must
add the appropriate keystrokes.
For example: The Change Display (COMMAND
49) function has three sub-functions: Bright
Display, Dim Display, and Date/Time Display.
- To turn up the display, enter:
[A][4][9][E]
- To dim the display, enter:
[A][4][9][D][E]
- To display time and date, enter:
[A][4][9][B][E]
Custom Functions can perform several tasks at one
time. For example:
To toggle relays 7, 8, and 9 in one Custom
Function enter:
[A] [5] [4] [7] [E] [E] [8] [E] [E] [9] [E] [E] [C]
To add a temporary passcode, enter:
[A] [5] [6] [3] [0] [E] [E] [9] [8] [7] [E] [E] [D]
[E] [1] [E] [1] [E] [1] [E] [1] [E] [1] [E] [1] [E] [1]
[E] [1] [E] [C]
This adds user 30, passcode 987 with authority
level 1 in all areas.
To delete the passcode, enter:
[A] [5] [3] [3] [0] [E] [E] [E] [C]