Bosch D7212GV2 Guia de Instalação Página 10

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 140
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 9
D7212GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 10
Bosch Security Systems, Inc. | 1/08 | F01U003804-04
Point/User Flag
Default: Yes
Selection:
Yes or No
Yes The control panel sends a flag with
each report telling the D6500/D6600
to convert point numbers and User ID
numbers to COMEX format. Refer to
Table 4 and Table 5 for conversion
information. When this parameter is
programmed Yes, points and User ID
numbers are converted, regardless of
the programming of the D6500 or
D6600 Receiver for output to the
computer system. Refer to Appendix C
in the Conettix D6600/D6100
Receiver/Gateway Computer Interface
Manual (P/N: 4998122703).
No The control panel does not send the
flag. The D6500/D6600 outputs point
numbers as 001 to 040 (rather than
100 to 216) and User ID numbers as
000 to 099 (rather than 000 to F08), as
indicated in Table 4 and Table 5.
This program item determines how point and User ID
numbers are presented at the D6500/D6600 display,
printer, and computer RS-232 output.
When
Modem Format
is Yes, the control panel sends
expanded Bosch Modem IIIa
2
Communication Format
reports to the D6500/D6600. If your central station
data files are not set up for point and User ID number
reporting, you can use this program item to convert
these numbers to COMEX Reports.
When
Modem Format
is Yes, the control panel sends
expanded Bosch Modem IIIa
2
Communication Format
Reports to the receiver.
Point/User Flag
affects Bosch
Modem IIIa
2
Communication Format data as shown in
Table 4. The Bosch Security Systems, Inc.
D6500/D6600 Receiver adds the leading zero in the
User ID number with
Point/User Flag
programmed
No.
Table 4: Modem IIIa
2
Communication Format
Data - User ID Numbers
Point/User Flag
NO
Point/User Flag
YES
000 000
001 to 005 001 to 005
006 to 013 601 to 608
014 to 021 701 to 708
022 to 029 801 to 808
030 to 037 B01 to B08
038 to 045 C01 to C08
046 to 053 D01 to D08
054 to 061 E01 to E08
062 to 069 F01 to F08
070 to 099 000
Table 5: Modem IIIa
2
Communication Format
Data – Point Numbers
Point/User Flag
NO
Point/User Flag
YES
001 to 008 100 to 800
009 to 024 101 to 116
025 to 040 201 to 216
041 to 056 301 to 316
Vista de página 9