Select this option to program a zone as silent. A silent zone does not activate the horn
speaker, bell, or strobe outputs. It activates the Silent Alarm output. The communicator and all
other programmable outputs function according to the parameters programmed for the zone.
8 – Sensor Watch
Sensor watch allows the control panel to recognize when detection devices might have
stopped working. This feature monitors the operation of a zone over the time period
programmed in Locations 476 and 477.
This value specifies how many 24-hour periods a zone can remain continuously sealed before
it registers as a Sensor Watch fault. The number of hours required to fulfill these 24-hour
periods is calculated only when the system is disarmed. Every time the system is armed in the
AWAY Mode, STAY Mode 1, or STAY Mode 2, the Sensor Watch Timer pauses its count. The
Sensor Watch Timer continues its count the next time the system is disarmed.
Example
If the Sensor Watch Time is programmed for 2 days and the premises is armed for 12 hours
and disarmed for 12 hours each day, it takes 4 days before a zone can register a Sensor Watch
fault.
Zone Options 2
This location has four programming options. You can select any combination of the options by
programming a single value. Calculate this value by adding the option bit numbers together.
Option Description
1 Isolate in STAY Mode 1
2 Zone Isolation Allowed
4 Forced Arming Allowed
8 Zone Restore Report
1 – Isolate in STAY Mode 1
If this option is selected, the zone can be automatically isolated when the system is armed in
STAY Mode 1.
If this option is not selected and the system is armed in STAY Mode 1, the zone activates an
alarm when activated as it normally would in AWAY Mode.
You can specify a global entry time for all zones, except for 24-Hour Zones, when the system is
armed in STAY Mode 1. You program this time in Locations 472 and 473. The Entry Guard
Timer overrides the delay time programmed for a Delay Zone. If you program the Entry Guard
Timer as 0, each zone acts according to its programmed zone type.
Refer to Arming the System in STAY Mode 1, page 53 for more information.
2 – Zone Isolation Allowed
If this option is selected, the operator can isolate the zone before arming the system. If this
option is not selected, the zone cannot be manually isolated. When a zone is manually
isolated, a Zone Bypass Report (Contact ID Event Code 570) is sent. Refer to Isolating zones,
page 56 for more information.
When isolating 24-Hour Zones, the system automatically sends a Zone Bypass Report when the
zone is selected to be isolated. All non-24-Hour zones send a Bypass Report only when the
system is armed.
4 – Forced Arming Allowed
9.3.6
94 en | Zone Information Control Panel
2014.07 | 00n | F01U298026 Installation Guide