Output Event Types
There are approximately 81 Output Event Types. Two numbers designate each Output Event
Type. Program these numbers into the appropriate locations for the output.
0,1 System Armed
This output operates when the system is armed. The output is reset when the system is
disarmed. If the system is partitioned, this output operates when both areas are armed in
AWAY Mode, STAY Mode 1 or STAY Mode 2.
0,2 System Disarmed
This output operates when the system is disarmed. The output is reset when the system is
armed. If the system is partitioned, this output operates when both areas are disarmed.
0,3 Armed in STAY Mode
This output operates when the system is armed in STAY Mode 1 or STAY Mode 2. The output is
reset when the system is disarmed. If the system is partitioned, this output operates when
either area is armed in STAY Mode 1 or STAY Mode 2.
0,4 Armed in AWAY Mode
This output operates when the system is armed in AWAY Mode. The output is reset when the
system is disarmed. If the system is partitioned, this output operates when either area is
armed in AWAY Mode.
0,5 Auto Arm Pre-Arming Alert Time
This output operates during the time period before the control panel is automatically armed in
AWAY Mode or STAY Mode 1. The output is reset when the control panel is automatically
armed in AWAY Mode or STAY Mode 1. The Auto Arming Pre-Alert Time is programmed in
Location 481.
0,6 Exit Warning with All Zones Sealed or Entry Warning
This output operates during Exit Time when the control panel is armed and all zones are
sealed. The output is reset when Exit Time expires.
This output operates again during Entry Time and is reset when Entry Time expires or the
system is disarmed.
This output also operates if a zone is activated when the system is armed in STAY Mode 1 or
STAY Mode 2 and the Entry Guard Timer for STAY Mode is programmed in Locations 472 and
473.
0,7 Exit Warning
This output operates during Exit Time when the system is armed. The output is reset when
Exit Time expires or the system is disarmed.
0,8 Exit Warning Finished
This output operates after Exit Time expires when the system is armed. The output is reset
when the system is disarmed.
0,9 Kiss-Off after Exit Time
This output operates after the first successful transmission to the base station receiver when
Exit Time expires. The output is reset when the system is disarmed.
0,11 Entry Warning
This output operates when during Entry Timer 1, Entry Timer 2, or Entry Guard Timer for STAY
Mode. The output is reset when the Entry Time or Entry Guard Time expires or the system is
disarmed. If Entry Time and Entry Guard time are present together, the output will follow the
Entry Guard Time.
0,12 Entry Warning + Day Alarm Resetting
This output combines Entry Warning and Day Alarm Resetting so that either of these two
events activates the output.
15.2
132 en | Programmable Outputs Control Panel
2014.07 | 00n | F01U298026 Installation Guide
Vista de página 131
1 2 ... 127 128 129 130 131 132 133 134 135 136 137 ... 151 152

Comentários a estes Manuais