If this option is not selected, the installer can connect to a control panel from any remote
location for Upload/Download operations without the control panel calling back to the remote
computer. The user can initiate a modem call from the codepad by holding down [6].
4 – Exit from upload/download connection on alarmExit from upload/download connection
on alarm
If an alarm occurs when the control panel is communicating with a remote computer using A-
Link Plus, the A-Link session is terminated and the relevant alarm message is transmitted to
the base station receiver.
If an alarm occurs that does not have to be reported to the base station receiver, the session
is not terminated.
Communicating with the B426/B450
PC/A-Link Soluon 2000/3000 Panel
B426 -1 B450-2
SwitcherRouter
GPRS
Internet
The configuration diagram above is an example of using B426 as network module 1 and B450
as network module 2. The wiring diagram is shown in above picture. “B426-1” means the
rotary address switch of B426 is set to 1; “B450-2” means the rotary address switch of B450
is set to 2.
There are 9 steps to configure the communication platform of A-Link, B426, B450 and a
Solution 2000/3000 control panel from factory default values.
Install Tera term
Install Tera Term from the B450 CD. A-Link Plus is used to configure parameters of the control
panel and network module. Tera Term is used to access the USB menu of B450.
Program the module address using the codepad
1. Enter the Installer passcode (the default is 1234) and press [#] to enter Installer’s
Programming Mode.
2. Press [8][1] to access the Address Program menu.
3. To reset the parameters to default values, press [9][6][1][#] then press [9][6][0][#]. The
control panel returns to the main interface and restores all of the parameters to factory
default values.
4. Enter the Installer passcode (the default is 1234) and press [#] to enter Installer’s
Programming Mode. Press [7][2][1] to access the Network Module menu. Set the two
modules to 1 – Used, Not Config.
5. Continue to press [-] until you return to Confirm to Save Parameter Changes.
6. Press [#] to save changes.
Configure the B426 network module
4.9.3
Control Panel Accessories | en 35
Installation Guide 2014.07 | 00n | F01U298026