System Event Timers
This section covers the features that involve timing, such as Entry and Exit Times, Sensor
Watch Time, and Siren Run Time.
Programming Entry/Exit Timers
There are two programming locations for Entry Timer 1, Entry Timer 2, Exit Time for AWAY
Mode, and Entry Guard Time for STAY Mode.
The first location of the timer allows you to set the timer in increments of 1 sec. The sec
location allows you to set the timer in increments of 16 sec. Add these two locations together
for the total time.
Example
To set the Entry Time to 18 sec, program Location 466 as 2 (2 x 1 sec = 2 sec) and Location
467 as 1 (1 x 16 sec = 16 sec) for a total time of 18 sec (2 + 16 =18).
Entry Timer 1
Location 466 to 467
Location Default
Increments of 1 sec (0 sec to 15 sec) 466 4
Increments of 16 sec (0 sec to 240 sec) 467 1
You can program Entry Timer 1 from 0 to 255 sec in increments of 1 sec. Entry Timer 1 is the
delay time used by the Delay-1 Zones.
Entry Timer 2
Location 468 to 467
Location Default
Increments of 1 sec (0 sec to 15 sec) 468 8
Increments of 16 sec (0 sec to 240 sec) 467 2
You can program Entry Timer 2 from 0 to 255 sec in increments of 1 sec. Entry Timer 2 is the
delay time used by Delay-2 Zones.
Exit Timer
Location 470 to 471
Location Default
Increments of 1 sec (0 sec to 15 sec) 470 12
Increments of 16 sec (0 sec to 240 sec) 471 3
10
10.1
10.2
10.3
10.4
Control Panel System Event Timers | en 101