Bosch DS7400XiV4-EXP Especificações Página 67

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 66
DS7400XiV4-EXP | Reference Guide | 5.0 Programming the Control Panel EN | 67
Bosch Security Systems | 1/05| 4998154963B
Table 90: Address 3153, Data Digit 2 (Zones)
Selections for Data
Digit 2
Select Options 1 2 3 7 *1 *5
Use Phone
Use DS7416i
Use Either
Use Both
Try Phone First
Phone/DS7416i Report Routing and Phone First Count
Phone First Count is used to control the number of attempts made on the phone line before switching to the
DS7416i. This value is only referenced if the “Use Phone”, “Use DS7416i”, and “Try Phone First” options are all
selected. If the value is less than or equal to 2, or more than 5, two attempts are made on the phone before trying
the DS7416i if the Phone First option is selected.
Address: 3154
Data Digit:
Data Digit 1 (System Reports): ____ (see Table 91; default = 3)
Data Digit 2 (Phone First Count): ____ (see Table 92; default = 0)
Selections:
Data Digit 1: 1 to 3, 7, *1, *5 (hexadecimal values that display as B and F at the keypads)
Data Digit 2: 0 to 9; *0 to *5 (hexadecimal values that display as A through F at the keypads)
Table 91: Address 3154, Data Digit 1
Selections for Data
Digit 1
Select Options 1 2 3 7 *1 *5
Use Phone
Use DS7416i
Use Either
Use Both
Try Phone First
Table 92: Address 3154, Data Digit 2
Select Option Value Select Option Value
0 Attempts
0
8 Attempts 8
1 Attempt 1 9 Attempts 9
2 Attempts 2 10 Attempts *0
3 Attempts 3 11 Attempts *1
4 Attempts 4 12 Attempts *2
5 Attempts 5 13 Attempts *3
6 Attempts 6 14 Attempts *4
7 Attempts 7 15 Attempts *5
Vista de página 66