Bosch DS7400XiV4-EXP Especificações Página 60

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 59
DS7400XiV4-EXP | Reference Guide | 5.0 Programming the Control Panel EN | 60
Bosch Security Systems | 1/05| 4998154963B
5.9.25 RS-232 Interface Configuration Programming
RS-232 Interface Configuration Programming allows you to configure the interface for your printer. Most printers
operate using the default values for the DS7412. Some printers might operate more efficiently using optional
program values.
Consult the operating guide provided with your printer to ensure that its configuration matches the one
programmed here.
If using the RPS Direct Connection option for programming, Address 4019 must be set for 1 0.
Address 4020 must be set for 2 5.
Address: 4020
Data Digit:
Data Digit 1: ____ (see Table 85; default = 0)
Data Digit 2: ____ (see Table 86; default = 0)
Selections: 0 to 5 for Data Digit 1; 0 to 7 for Data Digit 2.
Table 85: Address 4020, Data Digit 1
Select Option Value
300 baud
0
1200 baud 1
2400 baud 2
4800 baud 3
9600 baud 4
14400 baud 5
Table 86: Address 4020, Data Digit 2
Selections for Data Digit 2
Select Options 0 1 2 3 4 5 6 7
No Parity
ODD Parity
EVEN Parity
Software Flow Control
Hardware Flow Control
1 Stop Bit
2 Stop Bits
8 Data Bits