DS7400XiV4-EXP | Reference Guide | 6. Troubleshooting Guide EN | 101
Bosch Security Systems | 1/05| 4998154963B
Table 135: Keypad Troubleshooting (continued)
Symptom Probable Cause Possible Solutions
In history, the Read-back for the A, B,
and C keys shows:
A = Fire
B = Emergency
C = Panic
But, the Central Station transmissions
display B as Silent Panic and C as
Audible Panic.
Formats display information regarding
the B and C keys differently.
In Contact ID: A = Fire
B = Silent Panic
C = Audible Panic
In SIA: A = Fire
B = Emergency
C = Panic
Discrepancy exists in the definition of
these keys in the two formats.
Whatever the keys are programmed for
in the control panel, that is what is
sent.
Cannot perform a zone test (#81). a. Entering from a Master keypad.
b. Not using a PIN with test authority.
a. Zone test is not available from a
Master keypad.
b. Use a PIN with test authority.
Chime Mode (#7) does not work when
a zone is faulted.
a. Not activating for interior zones.
b. The keypad is not assigned to the
same area as the zone being
activated.
a. Chime mode only activates for
perimeter zones - Chime mode
must be programmed. Also, if the
perimeter zone has trouble
enabled (trouble on open), the
chime won't work if that zone is
opening.
b. Chime mode only activates the
sounder on keypads that are
assigned to the same area as the
zone.
Some functions do not work on a
Master keypad.
Some functions require you to enter
Single Partition Mode when using a
Master keypad.
The following commands require that
you are in Single Partition Mode when
entering from a Master keypad:
History read-back
Chime mode
Checking zone status
Checking zone trouble status
(after #87 - Master keypad only
shows area name)
Bypassing zones
6.2 Reporting Problems
Table 136: Reporting Troubleshooting
Symptom Probable Cause Possible Solutions
Does not send open or close reports. Not programmed correctly. Check addresses 3331, 3332, 3334,
and 3333.
Reports for areas 2-8 are being sent
with Area 1's reporting ID.
The account codes for 2 through 8 are
not programmed or are not
programmed correctly.
Check addresses 3429 through 3459.
Not getting AC power fail reports. a. AC power fail messages are sent
only with other reports, such as
low battery.
b. Check AC report offset (3338). If
00, AC report works like above, if
another number, AC report is
delayed.
a. Try forcing another report to send
when AC is not present.
b. Wait until the delay times out or
set to a lower number if desired.