Bosch DS7400XiV4-EXP Especificações Página 55

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 54
DS7400XiV4-EXP | Reference Guide | 5.0 Programming the Control Panel EN | 55
Bosch Security Systems | 1/05| 4998154963B
Table 70: Address 3151, Data Digit 1
(Open/Close)
Select Option Value
Alternate between both Phone Numbers
0
Report to Phone Number 1 1
Report to Phone Number 2 2
Report to Phone Number 1 and 2 3
Table 71: Address 3151, Data Digit 2 (Zones)
Select Option Value
Alternate between both Phone Numbers
0
Report to Phone Number 1 1
Report to Phone Number 2 2
Report to Phone Number 1 and 2 3
5.9.18 Report Control Programming
This section allows you to decide which phone number
sends reports other than Open/Close Reports and
Zone Reports.
Address: 3152
Data Digit:
Data Digit 1 (for Open and Close Reports):
____ (see Table 72)
Data Digit 2: Must = 0
Default: 0
Selections: 0 to 3
Table 72: Address 3152, Data Digit 1
(Report Control)
Select Option Value
Alternate between both Phone Numbers
0
Report to Phone Number 1 1
Report to Phone Number 2 2
Report to Phone Number 1 and 2 3
Data Digit 1 does not include Open and
Close Reports or Zone Reports. See
Sections 5.9.16 Open/Close Report
Control Programming and 5.9.17
Open/Close and Zone Report
Programming.
5.9.19 Entry and Exit Timer Programming (Program
Addresses 4028 to 4030)
Entry and Exit Delay Timers are in 5-second intervals.
The maximum delay time is 255 seconds.
For example:
01 (Data Digit 1 = 0, Data Digit 2 = 1) provides a
5-second timer
03 (Data Digit 1 = 0, Data Digit 2 = 3) provides a
15-second timer
12 (Data Digit 1 = 1, Data Digit 2 = 2) provides a
60-second timer
51 (Data Digit 1 = 5, Data Digit 2 = 1) provides a
255-second timer
Entry Delay Time 1
Address: 4028
Default: 09 (45 seconds)
Selections: 00 to 51 (0 to 255 seconds, in 5-second
intervals)
Entry Delay Time 2
Address: 4029
Default: 09 (45 seconds)
Selections: 00 to 51 (0 to 255 seconds, in 5-second
intervals)
Exit Delay Time
Address: 4030
Default: 12 (60 seconds)
Selections: 00 to 51 (0 to 255 seconds, in 5-second
intervals)
5.9.20 Fire and Burglary Bell Cutoff Programming
(Program Addresses 4032 to 4033)
Fire and Burglary Bell Cutoff timers are set in 1-minute
intervals. A value of 99 = 30-second cutoff.
For example:
01 (Data Digit 1 = 0, Data Digit 2 = 1) provides a
1-minute cutoff
03 (Data Digit 1 = 0, Data Digit 2 = 3) provides a
3-minute cutoff
12 (Data Digit 1 = 1, Data Digit 2 = 2) provides a
12-minute cutoff
99 (Data Digit 1 = 9, Data Digit 2 = 9) provides a
30-second cutoff
Vista de página 54
1 2 ... 50 51 52 53 54 55 56 57 58 59 60 ... 143 144

Comentários a estes Manuais

Sem comentários