DS7400XiV4-EXP | Reference Guide | 5.0 Programming the Control Panel EN | 47
Bosch Security Systems | 1/05| 4998154963B
5.9.12 Emergency Key Programming
Emergency Key and Panic Key programming disables or activates the A, B, and C keys located on the keypads
and/or keyfobs. See Figure 13.
Although there are no A, B, and C keys on a keyfob, you have to program A, B, and C keys for keyfob Panic
Keys to work. The user must hold down both the Arm and Disarm buttons to cause a panic alarm.
Emergency Key programming also determines a silent, pulsed, or steady alarm.
See Section 7.2.7 Emergency Key Programming for Emergency Key Programming glossary definitions.
See the DX7400XiV4 Wireless Reference Guide (P/N: 4998154790) for additional information.
• Addresses: 3147 to 3148
• Data Digit:
• Address 3147, Data Digit 1: ____ (see Table 52; default = 0)
• Address 3147, Data Digit 2: ____ (see Table 53; default = 0)
• Address 3148, Data Digit 1: ____ (see Table 54; default = 0)
• Address 3148, Data Digit 2: Must be 0
• Default: 0
• Selections: 0 to 3
Table 52: Address 3147 Data Digit 1, Fire Key A
Selections
Select Option Value
Fire Key Disabled
0
Fire Key = Disabled 1
Fire Key = Steady Alarm 2
Fire Key = Pulsed Alarm 3
NOTE: May be forced to a different value when in
Commercial Fire Mode. See Section 5.9.15
Commercial Fire Mode Programming.
Table 53: Address 3147 Data Digit 2, Emergency
Key B Selections
Select Option Value
Special Emergency Key Disabled
0
Special Emergency Key = Silent Alarm 1
Special Emergency Key = Steady Alarm 2
Special Emergency Key = Pulsed Alarm 3
Table 54: Address 3148 Data Digit 1, Panic Key C
Selections
Select Option Value
Panic Key Disabled
0
Panic Key = Silent Alarm 1
Panic Key = Steady Alarm 2
Panic Key = Pulsed Alarm 3
NOTE: May be forced to a different value when in
Commercial Fire Mode. See Section 5.9.15
Commercial Fire Mode Programming.
Figure 13: Emergency Keys
1 23
456
789
0
*
#
12345678
910
11
12 13
14
15
16
Armed
Status
Power
Fire
Perimeter
Supervisory
Bell Silenced
Trouble
System
Reset
Bypass
No
Entry
Perimeter
Only
Off
On
Armed
Status
Power
Fire
1 23
456
789
0
*
#
On
No
Entry
System
Reset
Bypass
Only
Perimet er
Off
TEST WEEKLY