PI -- 34.65dProduct Information MAGIC.SENS -- Product r ange
Page8of42
BDL--4998121218
A23.en /09.02.2007
ST--FIR/ PRM1 / deh
3. Planning Notes
MAGIC.SENS fire detectors are not intended for
external use!
3.1. Basic Planning Specifications
D T he planning of multisensor fire detectors (combination detectors) occurs
according to the guidelines for optical detectors until an independent guideline has
been worked out with the VdS.
D The types OTC, OC and OT are planned according to the guidelines for optical
detectors if they are operated as optical detectors or combined detectors; see
DIN VDE 0833 Part 2 and VDS 2095,
-- maximum m onitoring area 120m
2
,
-- installation height up to 16m.
D If the occasional switching--off of the optical unit (scattered light sensor) is
desired, the planning must occur according to the guidelines for h eat detectors;
see DIN VDE 0833 Part 2 and VDS 2095,
-- minimum monitoring area 40m
2
,
-- installation height maximum 7.5m for the T 400 E LSN or OT 400 E LSN
,
-- installation height maximum 6m for the T 300 GLT or OT 300 GLT.
D Maximum cable length: 1000m, for J --Y(St) Y n x 2 x 0.6 / 0.8.
D Maximum permissible air speed: 20
m
/
s
.
D When planning for fire barriers according to DIBt, the following m ust be taken
into account:
-- T 400 E LSN must be programmed according to class A1R,
-- the characteristic curve of the T 300 / F SA also corresponds to the A1R class.
3.2. Use on a Local Security Network (LSN)
On the LSN, up to 127 detectors can be operated in the following operating modes
depending on the loop or stub:
Operating mode
Detector type combined only opti cal only therm o--maximum only thermo --differential
OTC 410 LSN x x x x
OC 410 LSN x x -- --
OT 400 E LSN x x x x
O 400 E LSN -- x -- --
T 400 E L SN -- -- x x
3.3. Use with Conventional Line Technology
(German: Gleichstrom Linientechnik, abbreviated (GLT)
The GLT technology permits the connection of up to detectors to a primary line.