4.3 Allegiant Error Messages
Error Name Description
Error 01 Invalid Camera Request The camera number entered from the keyboard does not exist. If
using the optional LTC 8059/00 Master Control Software or the
LTC 8850/00 Graphical User Interface Software, ensure that the
number exists in the Camera Identification table. Download the
table to be sure.
Error 02 Invalid Monitor Request The monitor number entered from the keyboard does not exist.
Error 03 Remote Device Locked The remote device requested cannot be controlled, because it is locked
by User# by a user with equal or higher priority. Check with the other users or
request that a higher priority user unlock the remote device.
Error 04 Monitor Locked by User# The monitor requested cannot be accessed, because it is locked by
a user with equal or higher priority. Check with the other users or
request that a higher priority user unlock the monitor.
Error 05 Remote Device Access Restricted Remote locked out by Remote Lock Out table.
Error 06 Monitor Access Restricted Monitor locked out by Monitor Lock Out table.
Error 10 Access Denied A function was requested for which the user priority is too low. Only a
Priority 2 user or a supervisor with Priority 1 may access this function.
Error 11 Access Denied A function was requested for which the user priority is too low. Only
a supervisor with Priority 1 may access this function.
Error 15 Invalid User Function The function number requested from the keyboard is invalid. Refer to
the User Function table for a listing of valid user function numbers.
Error 20 Acknowledge Denied The ACKNOWLEDGE button was pressed by a user without the
authority to acknowledge alarms.
Error 21 Incorrect Acknowledge In order to properly acknowledge an alarm event, the keyboard must
be switched to a monitor that is displaying the alarms.
Error 22 Acknowledge Disabled Alarms on this monitor cannot be acknowledged, because that
capability has been disabled by the system programmer.
Error 23 Camera Not in Alarm The camera displayed on the monitor is not an alarm video; only
alarm-generated video can be acknowledged.
Error 24 Keyboard Not Enabled This keyboard may not acknowledge alarm video on this
for Acknowledge monitor; it has been disabled by the system programmer.
Error 25 Alarm Switcher Running Alarm video may only be acknowledged if the alarm switcher is not
running; press HOLD to stop the switcher.
Error 50 SEQUENCE Not Available The user attempted to load a switcher sequence that does not exist.
This is a good way to determine, from the keyboard, which sequence
numbers are unused when desiring to add one. A request was made
to load an ABSOLUTE type sequence, without the keyboard being
on one of the monitors in that sequence. Because inadvertent
loading of monitors should be avoided, the user is required to switch
his keyboard to one of the monitors used by the sequence. The
PROGRAM mode may be used to review which monitors are used
in the sequence.
Error 52 SEQUENCE Request A request was made to load a RELATIVE type sequence on a monitor
number that is too high; the monitors used by the sequence would
extend past the highest monitor. Try switching to a lower monitor number
before loading the sequence.