Bosch INTEGRUS Manual de Serviço Página 20

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 19
20 | en INTEGRUS | Digital Infra-red Language Distribution System
BOSCH Security Systems B.V.| February 2003
1.5.3 System with more than 4 carriers and a radiator under a balcony
Figure 1.29 illustrates a situation in which a radiation signal delay occurs and which can be compensated for. For systems with
more than four carriers, add one delay switch position per 10 meter (33 feet) difference in signal path length to the radiators
which are closest to the overlapping coverage area. In Figure 1.29 the signal path length difference is 12 meter. Add one delay
switch position to the calculated switch position(s) for the radiator(s) under the balcony.
Figure 1.29 Radiation path length difference for two radiators