Bosch INTEGRUS Manual de Serviço Página 19

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 18
INTEGRUS | Digital Infra-red Language Distribution System en | 19
BOSCH Security Systems | February 2003
Figure 1.28 System with master and slave transmitter in multi purpose room
Table 1.3 Calculation of the master-to-slave signal delays
Cable length
master-slave
transmitter [m]
Cable
signal delay
per meter [ns/m]
Cable
signal delay
[ns]
Signal delay
slave transmitter
[ns]
Master-to-slave
signal delay [ns]
50 5.6 50 x 5.6 = 280 33 280 + 33 = 313
Table 1.4 Calculation of the delay switch positions of a system with two transmitters
Radiator
number
Transmitter Master-to-
slave signal
delay [ns]
Cable signal
delay [ns]
Total signal
delay [ns]
Signal delay
difference
[ns]
Delay switch
position
1 Master 0 168 0+168 = 168 593-168 = 425 425/33 = 12.88 = 13
2 Master 0 280 0+280 = 280 593-280 = 313 313/33 = 9.48 = 9
3 Master 0 112 0+112 = 112 593-112 = 481 481/33 = 14.58 = 15
4 Master 0 168 0+168 = 168 593-168 = 425 425/33 = 12.88 = 13
5 Master 0 280 0+280 = 280 593-280 = 313 313/33 = 9.48 = 9
6 Slave 313 168 313+168 = 481 593-481 = 112 112/33 = 3.39 = 3
7 Slave 313 280 313+280 = 593 593-593 = 0 0/33 = 0
8 Slave 313 112 313+112 = 425 593-425 = 168 168/33 = 5.09 = 5
9 Slave 313 168 313+168 = 481 593-481 = 112 112/33 = 3.39 = 3
10 Slave 313 280 313+280 = 593 593-593 = 0 0/33 = 0