K2200 Series | Installation Guide | 6.0 Configuration and Testing EN | 50
Bosch Security Systems | 7/03 | 17375 1.3 / 46513C
ENTER TIME 15-53
Press [ENT] to save.
End of process. Press [ESC] to go back to the CMD
prompt.
The DL Command
The Download (DL) command sends the contents of
the master controller's database to all slave
controllers. This will ensure that all the door
controllers have the same information. (The slave
controllers need to be configured and address
properly in order for this command to function).
1. At the CMD prompt, type [D][L] and press [ENT].
CMD DL
2. Type [Y] and press [ENT] to confirm.
DLOAD TO ALL Y
3. From the CMD prompt, press the ESC key to exit
out of programming.
CMD_
4. You will see this message on the screen when
you leave programming mode.
SENDING DATA
It indicates the progress of the download, in this
example 26.9%. The download will be complete
when it reaches 100%. The message will
disappear when the download is completed.
DOWNLOAD 26-9
6.1.10 Testing Readers and Locks
If you programmed a master programming key in the
INST command, that key will have access through all
doors. You can now use this key to check the
operation of readers and locks.
Readers
1. Present the key to each reader:
2. The green LED should light on the reader and
remain on for the duration of the lock release
time.
3. The lock should operate for the duration of the
lock release time.
4. The faceplate should display the following (the
numbers indicating which doors are open):
DOORS OPEN 1
Door Monitoring
If door monitoring is being used:
1. Close the door before the lock release time
expires, the green LED on the reader should go
out and the door should lock.
2. Leave the door open after a valid card read, the
green LED on the reader will go out and the lock
will lock. After the expiry of the door open time,
you should get a door left open warning:
CH 1 – O --------
3. Open the door without presenting a key or
tripping the request to exit device. You should
immediately obtain a door alarm, flashing and
sounding, indicating which door has been forced:
DOOR 01 ALARM
4. You should get exactly the same effect by
disconnecting the reader terminal block - causing
a tamper alarm.
Note:
To silence the faceplate, present the Master
programming key to the faceplate reader
6.2 RS-232 Serial Port
The RS-232 serial port can be used to connect the
door controller to a variety of devices.
Note:
The printer connector is not currently used. The printer
is connected via the RS-232 connector.
6.2.1 Connecting a Printer
Faceplate:
A printer can only be fitted when the system is being
administered from the faceplate. When administered
from a PC, all printed output is generated by the PC.
Report Printing
All the information stored in the door controller
database can be printed. There are several printer
commands, P1 to P9, see Readykey
K2200 Series
Controllers User Guide (Bosch P/N: 47491, PAC P/N:
17376), which will allow particular reports to be
generated.
Transaction Printing
The door controller can store about 2400 transactions
in its memory. Each transaction is printed out if a
printer is connected. If the printer is not connected,
the transactions will be stored. Once the maximum
number of transactions is reached, the oldest ones
will be lost. When the printer is reconnected, printing
will continue with the oldest unprinted transaction
and continue until all unprinted transactions have
been output.