K2200 Series | Installation Guide | 6.0 Configuration and Testing EN | 47
Bosch Security Systems | 7/03 | 17375 1.3 / 46513C
For example, if you want a dial-back to be
initiated when a positive event occurs on doors 1
and 3 on door controller 1, type 1 and 3 and
press [ENT].
Press [ENT] to save, press [NXT] go on.
8. This allows programming of positive event dial-
back for door controller 2 (i.e. the controller with
address 2)
DIAL D/C2 DR----
Programming is identical to that for door
controller 1.
Press [ENT] to save, press [NXT] go on.
9. This allows programming of positive event dial-
back for door controller 3
DIAL D/C3 DR----
Programming is identical to that for door
controller 1.
Press [ENT] to save, press [NXT] go on.
10. This allows programming of positive event dial-
back for door controller 4
DIAL D/C4 DR----
Programming is identical to door controller 1.
Press [ENT] to save, press [NXT] go on.
11. This allows programming of positive event dial-
back for door controller 5
DIAL D/C5 DR----
Programming is identical for door controller 1.
Press [ENT] to save, press [NXT] go on.
12. This allows programming of positive event dial-
back for door controller 6
DIAL D/C6 DR----
Programming is identical for door controller 1.
Press [ENT] to save, press [NXT] go on.
13. This allows programming of positive event dial-
back for door controller 7
DIAL D/C7 DR----
Programming is identical for door controller 1.
Press [ENT] to save, press [NXT] go on.
14. This allows programming of positive event dial-
back for door controller 8.
DIAL D/C8 DR----
Programming is identical for door controller 1.
Press [ENT] to save, press [NXT] go on.
Note:
In order for dial-back on positive events to operate a
number of other settings need to be programmed.
In
Setting
mode, the following must be programmed:
CONNECT MODEM Y
Make sure that Y is programmed to indicate there is a
dial-up modem connected to this door controller.
SETUP –D------
Make sure that the D setting is programmed here to
enable
Dialback
. In the event of an alarm condition,
the door controller will dial-back to the Multi-Site
CNC. If a dial-back on positive transactions is also
required, the additional settings described above must
also be programmed.
In
EVENT
mode
,
the following must be programmed:
FRGT POS TRANS N
This setting must be programmed to N in order that all
positive transactions are not ignored, and hence initiate
dial-back to the CNC.
6.1.9 Programming Readers and Locks (For
Standalone Masters only, no software)
Having verified the operation of the readers and door
inputs, now you can verify the lock operation. To do
this you will need to program some values against
each door.
Note:
As these will be required when the system is
operational, it is sensible to use the correct information
for each door.
Get to the CMD prompt by presenting the master key
to the internal reader on the controller faceplate.
The D Command
This command allows settings to be made for each
door. You can use the up and down arrow keys to
move between doors (the door number DR n will
change). Use the [NXT] and - (minus) keys to move
between settings.
1. At the CMD prompt, type [D] and press [ENT].
CMD D
If you get an PC ADMIN ACTIVE message, you
will need to change PC ADMIN ACTIVE to [N]
to continue.
2. This is the number of seconds for which the lock
will operate. Type the required number of
seconds for the Door 1, Lock Release Time . (0-
255 seconds).
DR 1 LRT 5
Press [ENT] to save, [NXT] to go on.
3. Type the required number of seconds for the
Door 1, Door Open Time. (0-255 seconds).
DR 1 DOT 0
This is the amount of time, in seconds, after the
lock release time has expired, at which a door
left open warning will be given.