PART III: REFERENCE MATERIALS
7.0 Panel Event Descriptions
The following table lists the events generated by the control/communicator. Use this table for Basic Pager format and event
descriptions stored in the history log.
Event
#
Event Description
Event
#
Event Description
01 AC Fail AC power to panel is interrupted. 21 Auto On Extended Auto On Sked delayed 1 hour by user. Report
follows Open/Close routing.
02 AC Restore AC power to panel is restored. 22 Battery Low Panel backup battery is low.
03 Alarm, Tamper Alarm from detection device(s) that
has been tampered with.
23 Battery Missing Panel backup battery is missing. Very low,
shorted or open batteries are reported as
missing.
04 Alarm,
Emergency
Alarm from emergency detection
device(s), or ABC key programmed
for emergency response.
24 Rstrl Batt Low Battery restoral from low battery.
05 Alarm, Panic Alarm from panic/emergency
detection device(s).
25 Rstrl Batt Missing Battery restoral from missing battery.
06 Alarm, Invisible Alarm from detection device(s) that
does not appear at keypad during
alarm or trouble conditions.
26 Bypass, Fire User Selective bypass of fire detection device(s) by
user.
07 Alarm, 24-hr Burg Alarm from burglary detection
device(s) that are on 24 hours a
day.
27 Bypass, Fire, RPS Selective bypass of fire detection device(s) by
DS-RPS.
08 Alarm, Cntrl, Dly Alarm from detection device(s) with
Entry/Exit delays.
28 Bypass, Ctrl, User Selective bypass of controlled detection
device(s) by user.
09 Alarm, Cntrl Alarm from detection device(s) such
as keyswitches, motion detectors
(followers) or devices that initiate an
alarm immediately (do not follow any
Entry/Exit delays).
29 Bypass, Ctrl, RPS Selective bypass of controlled detection
device(s) by DS-RPS.
10 Cross, Tamper
Tamper alarm from detection
device(s) with Cross Zone option
selected.
30 Bypass, 24hr, User
Selective bypass of 24-hr non-fire detection
device(s) by user.
11 Cross,
Emergency
Emergency alarm from detection
device(s) with Cross Zone option
selected.
31 Bypass, 24hr, RPS Selective bypass of controlled detection
device(s) by DS-RPS.
12 Cross, Panic Panic alarm from detection device(s)
with Cross Zone option selected.
32 Bypass, Forced Zn Detection device(s) force armed at force
arming.
13 Cross, Invisible
Panic alarm from invisible detection
device(s) with Cross Zone option
selected.
33 Bypass, Swinger Zone swinger bypassed.
14 Cross, 24hr Burg Burglary alarm from detection
device(s) with Cross Zone option
selected.
34 UnBypass, Fire,
Usr
User cleared bypass (unbypass) of fire
detection device(s).
15 Cross, Cntrl, Dly Alarm from Entry/Exit detection
device(s) with Cross Zone option
selected.
35 UnBypass, Ctrl,
Usr
User cleared bypass (unbypass) of controlled
detection device(s).
16 Cross, Cntrl
Alarm from Keyswitch, Follower or
Instant detection device(s) with
Cross Zone option selected.
36
UnBypass, 24hr,
Usr
User cleared bypass (unbypass) of 24-hr
detection device(s).
17 Cross, Unverified
A fault on one non-fire zone type
with Cross Zone option selected.
This is not an alarm event.
37 Call for Service
Report sent automatically at Call for Service
Interval. It does not indicate a trouble
condition.
18 Alarm Exit Error Detection device(s) faulted at end of
Exit Delay.
38 Cancel Alarm User acknowledged active alarm before Bell
Time expired for non-fire detection device(s).
19 Alrm Recent Clse
Alarm event within two minutes of
closing.
39 Cancel Fire
User acknowledged active alarm before Bell
Time expired for fire detection device(s).
20 Alrm Recent Clse Alarm event within two minutes of
closing.
40 CheckSum Fail Checksum on panel’s parameters failed.
Contact Security Company to verify panel
program.
Table 18: Panel Event Descriptions